TY - DATA AB - MT is measured in the field by using induction coils to measure the time-varying magnetic source for frequencies between 1000-0.001~Hz, and electric dipoles to measure the Earth's electrical response. Because the magnetic source field is polarized, orthogonal directions of the fields need to be measured to get a complete description of the fields. In all measurements collected for this project, induction coils and electric dipoles were aligned with geomagnetic north and east. MT data were collected at 22 stations with a ZEN 32-bit data logger developed by Zonge International, magnetic fields were measured with ANT-4 induction coils, and electric fields where measured with Ag-AgCl reference electrodes from Borin on 50~m dipoles. The data was collected on a repeating schedule of 10~min at 4096~samples/s and 7 hours and 50 minutes at 256 samples/s over a 20-24 hour period. To convert time series data into the frequency domain and get estimations of the impedance tensor, the processing code BIRRP was used (Chave & Thompson 2004). Simultaneous measurements were used as remote references to reduce noise and bias in the data. Chave, A. D., & Thomson, D. J. 2004. Bounded inuence magnetotelluric response function estimation. Geophys. J. Int., 157, 988-1006. AU - Peacock, Jared AU - Shervais, John AU - Glen, Jonathan DB - Geothermal Data Repository DP - Open EI | National Renewable Energy Laboratory DO - 10.15121/1493809 KW - geothermal KW - energy KW - Snake River Plain KW - PFA KW - play fairway analysis KW - Idaho KW - Camas KW - Prairie KW - magnetotellurics KW - MT KW - data KW - resistivity KW - conductivity KW - electrical KW - geophysics KW - geophysical KW - SRP LA - English DA - 2018/05/06 PY - 2018 PB - United States Geological Survey T1 - Snake River Plain Geothermal Play Fairway Analysis Project MT Data UR - https://doi.org/10.15121/1493809 ER -