Table of Contents
Program Version:EnergyPlus, Version 9.4.0-217a24fc09, YMD=2024.04.11 16:19
Tabular Output Report in Format: HTML
Building: Building
Environment: BRYANT GEOTHERMAL (01-01:31-12) ** MI_ANN-ARBOR-MUNI-AP - USA Custom-725374 WMO#=725374
Simulation Timestamp: 2024-04-11
16:19:26
Table of Contents
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2024-04-11
16:19:26
Values gathered over 8760.00 hours
Site and Source Energy
|
Total Energy [kBtu] |
Energy Per Total Building Area [kBtu/ft2] |
Energy Per Conditioned Building Area [kBtu/ft2] |
Total Site Energy |
91346.72 |
109.06 |
109.06 |
Net Site Energy |
91346.72 |
109.06 |
109.06 |
Total Source Energy |
147131.77 |
175.66 |
175.66 |
Net Source Energy |
147131.77 |
175.66 |
175.66 |
Site to Source Energy Conversion Factors
|
Site=>Source Conversion Factor |
Electricity |
3.167 |
Natural Gas |
1.084 |
District Cooling |
1.056 |
District Heating |
3.613 |
Steam |
0.250 |
Gasoline |
1.050 |
Diesel |
1.050 |
Coal |
1.050 |
Fuel Oil No 1 |
1.050 |
Fuel Oil No 2 |
1.050 |
Propane |
1.050 |
Other Fuel 1 |
1.000 |
Other Fuel 2 |
1.000 |
Building Area
|
Area [ft2] |
Total Building Area |
837.58 |
Net Conditioned Building Area |
837.58 |
Unconditioned Building Area |
0.00 |
End Uses
|
Electricity [kBtu] |
Natural Gas [kBtu] |
Gasoline [kBtu] |
Diesel [kBtu] |
Coal [kBtu] |
Fuel Oil No 1 [kBtu] |
Fuel Oil No 2 [kBtu] |
Propane [kBtu] |
Other Fuel 1 [kBtu] |
Other Fuel 2 [kBtu] |
District Cooling [kBtu] |
District Heating [kBtu] |
Water [gal] |
Heating |
0.00 |
58300.92 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Cooling |
7580.72 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Interior Lighting |
2400.63 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Exterior Lighting |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Interior Equipment |
7087.09 |
2024.88 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Exterior Equipment |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Fans |
6028.03 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Pumps |
0.94 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Heat Rejection |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Humidification |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Heat Recovery |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Water Systems |
0.00 |
7923.50 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
9170.74 |
Refrigeration |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Generators |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Total End Uses |
23097.42 |
68249.30 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
9170.74 |
Note: Natural gas appears to be the principal heating source based on energy usage.
End Uses By Subcategory
|
Subcategory |
Electricity [kBtu] |
Natural Gas [kBtu] |
Gasoline [kBtu] |
Diesel [kBtu] |
Coal [kBtu] |
Fuel Oil No 1 [kBtu] |
Fuel Oil No 2 [kBtu] |
Propane [kBtu] |
Other Fuel 1 [kBtu] |
Other Fuel 2 [kBtu] |
District Cooling [kBtu] |
District Heating [kBtu] |
Water [gal] |
Heating |
General |
0.00 |
58300.92 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Cooling |
General |
7580.72 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Interior Lighting |
General |
2400.63 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Exterior Lighting |
General |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Interior Equipment |
General |
7087.09 |
2024.88 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Exterior Equipment |
General |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Fans |
General |
6028.03 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Pumps |
General |
0.94 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Heat Rejection |
General |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Humidification |
General |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Heat Recovery |
General |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Water Systems |
General |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
9170.74 |
|
Water Heater |
0.00 |
7923.50 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Refrigeration |
General |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Generators |
General |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Normalized Metrics
Utility Use Per Conditioned Floor Area
|
Electricity Intensity [kBtu/ft2] |
Natural Gas Intensity [kBtu/ft2] |
Gasoline Intensity [kBtu/ft2] |
Diesel Intensity [kBtu/ft2] |
Coal Intensity [kBtu/ft2] |
Fuel Oil No 1 Intensity [kBtu/ft2] |
Fuel Oil No 2 Intensity [kBtu/ft2] |
Propane Intensity [kBtu/ft2] |
Other Fuel 1 Intensity [kBtu/ft2] |
Other Fuel 2 Intensity [kBtu/ft2] |
District Cooling Intensity [kBtu/ft2] |
District Heating Intensity [kBtu/ft2] |
Water Intensity [gal/ft2] |
Lighting |
2.87 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
HVAC |
16.25 |
79.07 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
10.95 |
Other |
8.46 |
2.42 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Total |
27.58 |
81.48 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
10.95 |
Utility Use Per Total Floor Area
|
Electricity Intensity [kBtu/ft2] |
Natural Gas Intensity [kBtu/ft2] |
Gasoline Intensity [kBtu/ft2] |
Diesel Intensity [kBtu/ft2] |
Coal Intensity [kBtu/ft2] |
Fuel Oil No 1 Intensity [kBtu/ft2] |
Fuel Oil No 2 Intensity [kBtu/ft2] |
Propane Intensity [kBtu/ft2] |
Other Fuel 1 Intensity [kBtu/ft2] |
Other Fuel 2 Intensity [kBtu/ft2] |
District Cooling Intensity [kBtu/ft2] |
District Heating Intensity [kBtu/ft2] |
Water Intensity [gal/ft2] |
Lighting |
2.87 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
HVAC |
16.25 |
79.07 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
10.95 |
Other |
8.46 |
2.42 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Total |
27.58 |
81.48 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
10.95 |
Electric Loads Satisfied
|
Electricity [kBtu] |
Percent Electricity [%] |
Fuel-Fired Power Generation |
0.000 |
0.00 |
High Temperature Geothermal* |
0.000 |
0.00 |
Photovoltaic Power |
0.000 |
0.00 |
Wind Power |
0.000 |
0.00 |
Power Conversion |
0.000 |
0.00 |
Net Decrease in On-Site Storage |
0.000 |
0.00 |
Total On-Site Electric Sources |
0.000 |
0.00 |
|
|
|
Electricity Coming From Utility |
23097.419 |
100.00 |
Surplus Electricity Going To Utility |
0.000 |
0.00 |
Net Electricity From Utility |
23097.419 |
100.00 |
|
|
|
Total On-Site and Utility Electric Sources |
23097.419 |
100.00 |
Total Electricity End Uses |
23097.419 |
100.00 |
On-Site Thermal Sources
|
Heat [kBtu] |
Percent Heat [%] |
Water-Side Heat Recovery |
0.00 |
|
Air to Air Heat Recovery for Cooling |
0.00 |
|
Air to Air Heat Recovery for Heating |
0.00 |
|
High-Temperature Geothermal* |
0.00 |
|
Solar Water Thermal |
0.00 |
|
Solar Air Thermal |
0.00 |
|
Total On-Site Thermal Sources |
0.00 |
|
Water Source Summary
|
Water [gal] |
Percent Water [%] |
Rainwater Collection |
0.00 |
0.00 |
Condensate Collection |
0.00 |
0.00 |
Groundwater Well |
0.00 |
0.00 |
Total On Site Water Sources |
0.00 |
0.00 |
- |
- |
- |
Initial Storage |
0.00 |
0.00 |
Final Storage |
0.00 |
0.00 |
Change in Storage |
0.00 |
0.00 |
- |
- |
- |
Water Supplied by Utility |
9170.74 |
100.00 |
- |
- |
- |
Total On Site, Change in Storage, and Utility Water Sources |
9170.74 |
100.00 |
Total Water End Uses |
9170.74 |
100.00 |
Setpoint Not Met Criteria
|
Degrees [deltaF] |
Tolerance for Zone Heating Setpoint Not Met Time |
2.00 |
Tolerance for Zone Cooling Setpoint Not Met Time |
2.00 |
Comfort and Setpoint Not Met Summary
|
Facility [Hours] |
Time Setpoint Not Met During Occupied Heating |
333.50 |
Time Setpoint Not Met During Occupied Cooling |
107.83 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 |
4088.50 |
Note 1: An asterisk (*) indicates that the feature is not yet implemented.
Table of Contents
Top
Annual Building Utility Performance Summary
Input Verification and Results Summary
Demand End Use Components Summary
Source Energy End Use Components Summary
Component Sizing Summary
Adaptive Comfort Summary
Climatic Data Summary
Envelope Summary
Lighting Summary
Equipment Summary
HVAC Sizing Summary
System Summary
Outdoor Air Summary
Object Count Summary
Energy Meters
Sensible Heat Gain Summary
Standard 62.1 Summary
LEED Summary
Zone Component Load Summary
|
BLOCK:ZONE1 |
Table of Contents
Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2024-04-11
16:19:26
General
|
Value |
Program Version and Build |
EnergyPlus, Version 9.4.0-217a24fc09, YMD=2024.04.11 16:19 |
RunPeriod |
BRYANT GEOTHERMAL (01-01:31-12) |
Weather File |
MI_ANN-ARBOR-MUNI-AP - USA Custom-725374 WMO#=725374 |
Latitude [deg] |
42.22 |
Longitude [deg] |
-83.7 |
Elevation [ft] |
820.25 |
Time Zone |
-5.0 |
North Axis Angle [deg] |
0.00 |
Rotation for Appendix G [deg] |
0.00 |
Hours Simulated [hrs] |
8760.00 |
ENVELOPE
Window-Wall Ratio
|
Total |
North (315 to 45 deg) |
East (45 to 135 deg) |
South (135 to 225 deg) |
West (225 to 315 deg) |
Gross Wall Area [ft2] |
936.09 |
200.02 |
268.03 |
200.02 |
268.03 |
Above Ground Wall Area [ft2] |
936.09 |
200.02 |
268.03 |
200.02 |
268.03 |
Window Opening Area [ft2] |
107.21 |
0.00 |
53.61 |
0.00 |
53.61 |
Gross Window-Wall Ratio [%] |
11.45 |
0.00 |
20.00 |
0.00 |
20.00 |
Above Ground Window-Wall Ratio [%] |
11.45 |
0.00 |
20.00 |
0.00 |
20.00 |
Conditioned Window-Wall Ratio
|
Total |
North (315 to 45 deg) |
East (45 to 135 deg) |
South (135 to 225 deg) |
West (225 to 315 deg) |
Gross Wall Area [ft2] |
936.09 |
200.02 |
268.03 |
200.02 |
268.03 |
Above Ground Wall Area [ft2] |
936.09 |
200.02 |
268.03 |
200.02 |
268.03 |
Window Opening Area [ft2] |
107.21 |
0.00 |
53.61 |
0.00 |
53.61 |
Gross Window-Wall Ratio [%] |
11.45 |
0.00 |
20.00 |
0.00 |
20.00 |
Above Ground Window-Wall Ratio [%] |
11.45 |
0.00 |
20.00 |
0.00 |
20.00 |
Skylight-Roof Ratio
|
Total |
Gross Roof Area [ft2] |
837.58 |
Skylight Area [ft2] |
0.00 |
Skylight-Roof Ratio [%] |
0.00 |
PERFORMANCE
Zone Summary
|
Area [ft2] |
Conditioned (Y/N) |
Part of Total Floor Area (Y/N) |
Volume [ft3] |
Multipliers |
Above Ground Gross Wall Area [ft2] |
Underground Gross Wall Area [ft2] |
Window Glass Area [ft2] |
Opening Area [ft2] |
Lighting [Btu/h-ft2] |
People [ft2 per person] |
Plug and Process [Btu/h-ft2] |
BLOCK:ZONE1 |
837.58 |
Yes |
Yes |
6700.98 |
1.00 |
936.09 |
0.00 |
96.60 |
107.21 |
0.8529 |
500.05 |
1.5353 |
Total |
837.58 |
|
|
6700.98 |
|
936.09 |
0.00 |
96.60 |
107.21 |
0.8529 |
500.05 |
1.5353 |
Conditioned Total |
837.58 |
|
|
6700.98 |
|
936.09 |
0.00 |
96.60 |
107.21 |
0.8529 |
500.05 |
1.5353 |
Unconditioned Total |
0.00 |
|
|
0.00 |
|
0.00 |
0.00 |
0.00 |
0.00 |
|
|
|
Not Part of Total |
0.00 |
|
|
0.00 |
|
0.00 |
0.00 |
0.00 |
0.00 |
|
|
|
Table of Contents
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2024-04-11
16:19:26
End Uses
|
Electricity [kBtuh] |
Natural Gas [kBtuh] |
Gasoline [kBtuh] |
Diesel [kBtuh] |
Coal [kBtuh] |
Fuel Oil No 1 [kBtuh] |
Fuel Oil No 2 [kBtuh] |
Propane [kBtuh] |
Other Fuel 1 [kBtuh] |
Other Fuel 2 [kBtuh] |
District Cooling [kBtuh] |
Steam [kBtuh] |
Water [gal/min] |
Time of Peak |
15-JUN-17:10 |
29-JAN-06:10 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
12-MAY-06:00 |
Heating |
0.00 |
40.30 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Cooling |
9.02 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Interior Lighting |
0.43 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Exterior Lighting |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Interior Equipment |
1.00 |
0.20 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Exterior Equipment |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Fans |
1.18 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Pumps |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Heat Rejection |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Humidification |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Heat Recovery |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Water Systems |
0.00 |
0.99 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.02 |
Refrigeration |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Generators |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Total End Uses |
11.63 |
41.49 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.02 |
End Uses By Subcategory
|
Subcategory |
Electricity [kBtuh] |
Natural Gas [kBtuh] |
Gasoline [kBtuh] |
Diesel [kBtuh] |
Coal [kBtuh] |
Fuel Oil No 1 [kBtuh] |
Fuel Oil No 2 [kBtuh] |
Propane [kBtuh] |
Other Fuel 1 [kBtuh] |
Other Fuel 2 [kBtuh] |
District Cooling [kBtuh] |
Steam [kBtuh] |
Water [gal/min] |
Heating |
General |
0.00 |
40.30 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Cooling |
General |
9.02 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Interior Lighting |
General |
0.43 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Exterior Lighting |
General |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Interior Equipment |
General |
1.00 |
0.20 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Exterior Equipment |
General |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Fans |
General |
1.18 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Pumps |
General |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Heat Rejection |
General |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Humidification |
General |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Heat Recovery |
General |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Water Systems |
General |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.02 |
|
Water Heater |
0.00 |
0.99 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Refrigeration |
General |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Generators |
General |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Table of Contents
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2024-04-11
16:19:26
Values gathered over 8760.00 hours
Source Energy End Use Components Summary
|
Source Electricity [kBtu] |
Source Natural Gas [kBtu] |
Source Gasoline [kBtu] |
Source Diesel [kBtu] |
Source Coal [kBtu] |
Source Fuel Oil No 1 [kBtu] |
Source Fuel Oil No 2 [kBtu] |
Source Propane [kBtu] |
Source Other Fuel 1 [kBtu] |
Source Other Fuel 2 [kBtu] |
Source District Cooling [kBtu] |
Source District Heating [kBtu] |
Heating |
0.00 |
63198.19 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Cooling |
24008.15 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Interior Lighting |
7602.81 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Exterior Lighting |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Interior Equipment |
22444.82 |
2194.97 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Exterior Equipment |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Fans |
19090.77 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Pumps |
2.97 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Heat Rejection |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Humidification |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Heat Recovery |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Water Systems |
0.00 |
8589.08 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Refrigeration |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Generators |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Total Source Energy End Use Components |
73149.53 |
73982.24 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Normalized Metrics
Source Energy End Use Components Per Conditioned Floor Area
|
Source Electricity [kBtu/ft2] |
Source Natural Gas [kBtu/ft2] |
Source Gasoline [kBtu/ft2] |
Source Diesel [kBtu/ft2] |
Source Coal [kBtu/ft2] |
Source Fuel Oil No 1 [kBtu/ft2] |
Source Fuel Oil No 2 [kBtu/ft2] |
Source Propane [kBtu/ft2] |
Source Other Fuel 1 [kBtu/ft2] |
Source Other Fuel 2 [kBtu/ft2] |
Source District Cooling [kBtu/ft2] |
Source District Heating [kBtu/ft2] |
Heating |
0.00 |
75.45 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Cooling |
28.66 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Interior Lighting |
9.08 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Exterior Lighting |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Interior Equipment |
26.80 |
2.62 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Exterior Equipment |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Fans |
22.79 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Pumps |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Heat Rejection |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Humidification |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Heat Recovery |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Water Systems |
0.00 |
10.25 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Refrigeration |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Generators |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Total Source Energy End Use Components |
87.33 |
88.33 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Source Energy End Use Components Per Total Floor Area
|
Source Electricity [kBtu/ft2] |
Source Natural Gas [kBtu/ft2] |
Source Gasoline [kBtu/ft2] |
Source Diesel [kBtu/ft2] |
Source Coal [kBtu/ft2] |
Source Fuel Oil No 1 [kBtu/ft2] |
Source Fuel Oil No 2 [kBtu/ft2] |
Source Propane [kBtu/ft2] |
Source Other Fuel 1 [kBtu/ft2] |
Source Other Fuel 2 [kBtu/ft2] |
Source District Cooling [kBtu/ft2] |
Source District Heating [kBtu/ft2] |
Heating |
0.00 |
75.45 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Cooling |
28.66 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Interior Lighting |
9.08 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Exterior Lighting |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Interior Equipment |
26.80 |
2.62 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Exterior Equipment |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Fans |
22.79 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Pumps |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Heat Rejection |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Humidification |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Heat Recovery |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Water Systems |
0.00 |
10.25 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Refrigeration |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Generators |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Total Source Energy End Use Components |
87.33 |
88.33 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Table of Contents
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2024-04-11
16:19:26
AirTerminal:SingleDuct:ConstantVolume:NoReheat
|
Design Size Maximum Air Flow Rate [ft3/min] |
BLOCK:ZONE1 SINGLE DUCT CAV NO REHEAT |
1127.47 |
User-Specified values were used. Design Size values were used if no User-Specified values were provided.
ZoneHVAC:PackagedTerminalAirConditioner
|
Design Size Cooling Supply Air Flow Rate [ft3/min] |
Design Size Heating Supply Air Flow Rate [ft3/min] |
Design Size No Load Supply Air Flow Rate [ft3/min] |
Design Size Outdoor Air Flow Rate During Cooling Operation [ft3/min] |
Design Size Outdoor Air Flow Rate During Heating Operation [ft3/min] |
Design Size Outdoor Air Flow Rate When No Cooling or Heating is Needed [ft3/min] |
BLOCK:ZONE1 PTAC |
1127.47 |
1127.47 |
1127.47 |
58.65 |
58.65 |
58.65 |
User-Specified values were used. Design Size values were used if no User-Specified values were provided.
Coil:Cooling:DX:SingleSpeed
|
Design Size Rated Air Flow Rate [ft3/min] |
Design Size Gross Rated Total Cooling Capacity [ton] |
Design Size Gross Rated Sensible Heat Ratio |
BLOCK:ZONE1 PTAC DX COOLING COIL |
1127.47 |
3.65 |
0.710334 |
User-Specified values were used. Design Size values were used if no User-Specified values were provided.
Coil:Heating:Electric
|
Design Size Nominal Capacity [Btu/h] |
BLOCK:ZONE1 PTAC HEATING COIL |
33044.24 |
User-Specified values were used. Design Size values were used if no User-Specified values were provided.
Fan:OnOff
|
Design Size Maximum Flow Rate [ft3/min] |
BLOCK:ZONE1 PTAC SUPPLY FAN |
1127.47 |
User-Specified values were used. Design Size values were used if no User-Specified values were provided.
AirLoopHVAC
|
Sum of Air Terminal Maximum Heating Flow Rates [ft3/min] |
Sum of Air Terminal Minimum Heating Flow Rates [ft3/min] |
Sum of Air Terminal Maximum Flow Rates [ft3/min] |
Adjusted Heating Design Air Flow Rate [ft3/min] |
Adjusted Cooling Design Air Flow Rate [ft3/min] |
Adjusted Main Design Air Flow Rate [ft3/min] |
User Heating Air Flow Ratio [] |
Calculated Heating Air Flow Ratio [] |
Design Supply Air Flow Rate [ft3/min] |
AIR LOOP |
1127.47 |
1127.47 |
1127.47 |
1127.47 |
1127.47 |
1127.47 |
1.00 |
1.00 |
1127.47 |
User-Specified values were used. Design Size values were used if no User-Specified values were provided.
Controller:OutdoorAir
|
Maximum Outdoor Air Flow Rate [ft3/min] |
Minimum Outdoor Air Flow Rate [ft3/min] |
AIR LOOP AHU OUTDOOR AIR CONTROLLER |
1127.47 |
58.65 |
User-Specified values were used. Design Size values were used if no User-Specified values were provided.
Coil:Heating:Fuel
|
Design Size Nominal Capacity [Btu/h] |
AIR LOOP AHU HEATING COIL |
32802.12 |
User-Specified values were used. Design Size values were used if no User-Specified values were provided.
Fan:ConstantVolume
|
Design Size Maximum Flow Rate [ft3/min] |
AIR LOOP AHU SUPPLY FAN |
1127.47 |
User-Specified values were used. Design Size values were used if no User-Specified values were provided.
PlantLoop
|
Maximum Loop Flow Rate [ft3/min] |
Plant Loop Volume [ft3] |
DHW LOOP |
0.003180 |
0.006362 |
User-Specified values were used. Design Size values were used if no User-Specified values were provided.
Pump:VariableSpeed
|
Design Flow Rate [ft3/min] |
Design Power Consumption [Btu/h] |
DHW LOOP SUPPLY PUMP |
0.003180 |
0.145919 |
User-Specified values were used. Design Size values were used if no User-Specified values were provided.
WaterHeater:Mixed
|
Use Side Design Flow Rate [ft3/min] |
Tank Volume [ft3] |
Maximum Heater Capacity [Btu/h] |
DHW LOOP WATER HEATER |
0.003180 |
0.114520 |
910.11 |
User-Specified values were used. Design Size values were used if no User-Specified values were provided.
Table of Contents
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2024-04-11
16:19:26
Time Not Meeting the Adaptive Comfort Models during Occupied Hours
|
ASHRAE55 90% Acceptability Limits [Hours] |
ASHRAE55 80% Acceptability Limits [Hours] |
CEN15251 Category I Acceptability Limits [Hours] |
CEN15251 Category II Acceptability Limits [Hours] |
CEN15251 Category III Acceptability Limits [Hours] |
Table of Contents
Report: Zone Component Load Summary
For: BLOCK:ZONE1
Timestamp: 2024-04-11
16:19:26
Estimated Cooling Peak Load Components
|
Sensible - Instant [Btu/h] |
Sensible - Delayed [Btu/h] |
Sensible - Return Air [Btu/h] |
Latent [Btu/h] |
Total [Btu/h] |
%Grand Total |
Related Area [ft2] |
Total per Area [Btu/h-ft2] |
People |
317.71 |
88.70 |
|
214.79 |
621.20 |
4.23 |
837.58 |
2.53 |
Lights |
33.34 |
153.17 |
0.00 |
|
186.51 |
1.27 |
837.58 |
0.76 |
Equipment |
1028.73 |
148.89 |
|
0.00 |
1177.61 |
8.03 |
837.58 |
4.80 |
Refrigeration |
0.00 |
|
0.00 |
0.00 |
0.00 |
0.00 |
837.58 |
0.00 |
Water Use Equipment |
0.00 |
|
|
0.00 |
0.00 |
0.00 |
837.58 |
0.00 |
HVAC Equipment Losses |
0.00 |
0.00 |
|
|
0.00 |
0.00 |
|
|
Power Generation Equipment |
0.00 |
0.00 |
|
|
0.00 |
0.00 |
|
|
DOAS Direct to Zone |
0.00 |
|
|
0.00 |
0.00 |
0.00 |
|
|
Infiltration |
2585.84 |
|
|
2882.05 |
5467.89 |
37.28 |
936.09 |
19.93 |
Zone Ventilation |
0.00 |
|
|
0.00 |
0.00 |
0.00 |
|
|
Interzone Mixing |
0.00 |
|
|
0.00 |
0.00 |
0.00 |
|
|
Roof |
|
2111.97 |
|
|
2111.97 |
14.40 |
837.58 |
8.60 |
Interzone Ceiling |
|
0.00 |
|
|
0.00 |
0.00 |
0.00 |
|
Other Roof |
|
0.00 |
|
|
0.00 |
0.00 |
837.58 |
0.00 |
Exterior Wall |
|
326.01 |
|
|
326.01 |
2.22 |
936.09 |
1.19 |
Interzone Wall |
|
0.00 |
|
|
0.00 |
0.00 |
0.00 |
|
Ground Contact Wall |
|
0.00 |
|
|
0.00 |
0.00 |
0.00 |
|
Other Wall |
|
0.00 |
|
|
0.00 |
0.00 |
936.09 |
0.00 |
Exterior Floor |
|
0.00 |
|
|
0.00 |
0.00 |
0.00 |
|
Interzone Floor |
|
0.00 |
|
|
0.00 |
0.00 |
0.00 |
|
Ground Contact Floor |
|
-105.7 |
|
|
-105.7 |
-0.7 |
837.58 |
-0.4 |
Other Floor |
|
0.00 |
|
|
0.00 |
0.00 |
0.00 |
|
Fenestration Conduction |
1631.15 |
|
|
|
1631.15 |
11.12 |
48.30 |
115.23 |
Fenestration Solar |
|
3251.96 |
|
|
3251.96 |
22.17 |
48.30 |
229.72 |
Opaque Door |
|
0.00 |
|
|
0.00 |
0.00 |
0.00 |
|
Grand Total |
5596.77 |
5975.03 |
0.00 |
3096.84 |
14668.63 |
|
|
|
Cooling Peak Conditions
|
Value |
Time of Peak Load |
6/15 17:20:00 |
Outside Dry Bulb Temperature [F] |
85.80 |
Outside Wet Bulb Temperature [F] |
73.01 |
Outside Humidity Ratio at Peak [lbWater/lbAir] |
0.01451 |
Zone Dry Bulb Temperature [F] |
70.99 |
Zone Relative Humidity [%] |
65.29 |
Zone Humidity Ratio at Peak [lbWater/lbAir] |
0.01056 |
Supply Air Temperature [F] |
45.00 |
Mixed Air Temperature [F] |
|
Main Fan Air Flow [ft3/min] |
415.01 |
Outside Air Flow [ft3/min] |
58.65 |
Peak Sensible Load with Sizing Factor [Btu/h] |
13256.77 |
Difference Due to Sizing Factor [Btu/h] |
1729.14 |
Peak Sensible Load [Btu/h] |
11527.62 |
Estimated Instant + Delayed Sensible Load [Btu/h] |
11571.79 |
Difference Between Peak and Estimated Sensible Load [Btu/h] |
-44.2 |
Engineering Checks for Cooling
|
Value |
Outside Air Fraction [fraction] |
0.1413 |
Airflow per Floor Area [ft3/min-ft2] |
4.956E-01 |
Airflow per Total Capacity [ft3-h/min-Btu] |
2.909E-03 |
Floor Area per Total Capacity [ft2-h/Btu] |
6.318E-02 |
Total Capacity per Floor Area [Btu/h-ft2] |
1.583E+01 |
Number of People |
1.7 |
Estimated Heating Peak Load Components
|
Sensible - Instant [Btu/h] |
Sensible - Delayed [Btu/h] |
Sensible - Return Air [Btu/h] |
Latent [Btu/h] |
Total [Btu/h] |
%Grand Total |
Related Area [ft2] |
Total per Area [Btu/h-ft2] |
People |
0.00 |
0.00 |
|
0.00 |
0.00 |
-0.00 |
837.58 |
0.00 |
Lights |
0.00 |
0.00 |
0.00 |
|
0.00 |
-0.00 |
837.58 |
0.00 |
Equipment |
0.00 |
0.00 |
|
0.00 |
0.00 |
-0.00 |
837.58 |
0.00 |
Refrigeration |
0.00 |
|
0.00 |
0.00 |
0.00 |
-0.00 |
837.58 |
0.00 |
Water Use Equipment |
0.00 |
|
|
0.00 |
0.00 |
-0.00 |
837.58 |
0.00 |
HVAC Equipment Losses |
0.00 |
0.00 |
|
|
0.00 |
-0.00 |
|
|
Power Generation Equipment |
0.00 |
0.00 |
|
|
0.00 |
-0.00 |
|
|
DOAS Direct to Zone |
0.00 |
|
|
0.00 |
0.00 |
-0.00 |
|
|
Infiltration |
-13792.3 |
|
|
-2338.4 |
-16130.7 |
63.91 |
936.09 |
-58.8 |
Zone Ventilation |
0.00 |
|
|
0.00 |
0.00 |
-0.00 |
|
|
Interzone Mixing |
0.00 |
|
|
0.00 |
0.00 |
-0.00 |
|
|
Roof |
|
-1696.3 |
|
|
-1696.3 |
6.72 |
837.58 |
-6.9 |
Interzone Ceiling |
|
0.00 |
|
|
0.00 |
-0.00 |
0.00 |
|
Other Roof |
|
0.00 |
|
|
0.00 |
-0.00 |
837.58 |
0.00 |
Exterior Wall |
|
-4567.1 |
|
|
-4567.1 |
18.10 |
936.09 |
-16.6 |
Interzone Wall |
|
0.00 |
|
|
0.00 |
-0.00 |
0.00 |
|
Ground Contact Wall |
|
0.00 |
|
|
0.00 |
-0.00 |
0.00 |
|
Other Wall |
|
0.00 |
|
|
0.00 |
-0.00 |
936.09 |
0.00 |
Exterior Floor |
|
0.00 |
|
|
0.00 |
-0.00 |
0.00 |
|
Interzone Floor |
|
0.00 |
|
|
0.00 |
-0.00 |
0.00 |
|
Ground Contact Floor |
|
75.98 |
|
|
75.98 |
-0.3 |
837.58 |
0.31 |
Other Floor |
|
0.00 |
|
|
0.00 |
-0.00 |
0.00 |
|
Fenestration Conduction |
-2920.7 |
|
|
|
-2920.7 |
11.57 |
48.30 |
-206.3 |
Fenestration Solar |
|
0.00 |
|
|
0.00 |
-0.00 |
48.30 |
0.00 |
Opaque Door |
|
0.00 |
|
|
0.00 |
-0.00 |
0.00 |
|
Grand Total |
-16713.0 |
-6187.4 |
0.00 |
-2338.4 |
-25238.8 |
|
|
|
Heating Peak Conditions
|
Value |
Time of Peak Load |
1/15 24:00:00 |
Outside Dry Bulb Temperature [F] |
0.30 |
Outside Wet Bulb Temperature [F] |
0.30 |
Outside Humidity Ratio at Peak [lbWater/lbAir] |
0.00082 |
Zone Dry Bulb Temperature [F] |
71.00 |
Zone Relative Humidity [%] |
21.62 |
Zone Humidity Ratio at Peak [lbWater/lbAir] |
0.00346 |
Supply Air Temperature [F] |
95.00 |
Mixed Air Temperature [F] |
|
Main Fan Air Flow [ft3/min] |
901.98 |
Outside Air Flow [ft3/min] |
58.65 |
Peak Sensible Load with Sizing Factor [Btu/h] |
-28654.0 |
Difference Due to Sizing Factor [Btu/h] |
-5730.8 |
Peak Sensible Load [Btu/h] |
-22923.2 |
Estimated Instant + Delayed Sensible Load [Btu/h] |
-22900.4 |
Difference Between Peak and Estimated Sensible Load [Btu/h] |
-22.8 |
Engineering Checks for Heating
|
Value |
Outside Air Fraction [fraction] |
0.0650 |
Airflow per Floor Area [ft3/min-ft2] |
1.077E+00 |
Airflow per Total Capacity [ft3-h/min-Btu] |
-2.925E-03 |
Floor Area per Total Capacity [ft2-h/Btu] |
-2.923E-02 |
Total Capacity per Floor Area [Btu/h-ft2] |
-3.421E+01 |
Number of People |
1.7 |
Table of Contents
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2024-04-11
16:19:26
SizingPeriod:DesignDay
|
Maximum Dry Bulb [F] |
Daily Temperature Range [deltaF] |
Humidity Value |
Humidity Type |
Wind Speed [ft/min] |
Wind Direction |
SUMMER DESIGN DAY IN BRYANT GEOTHERMAL (01-01:31-12) JUN |
89.80 |
23.10 |
73.40 |
Wetbulb [F] |
0.00 |
0.00 |
WINTER DESIGN DAY IN BRYANT GEOTHERMAL (01-01:31-12) |
0.30 |
0.00 |
0.30 |
Wetbulb [F] |
393.70 |
240.00 |
Weather Statistics File
Table of Contents
Report: Envelope Summary
For: Entire Facility
Timestamp: 2024-04-11
16:19:26
Opaque Exterior
|
Construction |
Reflectance |
U-Factor with Film [Btu/h-ft2-F] |
U-Factor no Film [Btu/h-ft2-F] |
Gross Area [ft2] |
Net Area [ft2] |
Azimuth [deg] |
Tilt [deg] |
Cardinal Direction |
BLOCK:ZONE1_WALL_2_0_0 |
HIGH PERFORMING PROJECT WALL R-12 |
0.30 |
0.084 |
0.090 |
268.03 |
214.42 |
90.00 |
90.00 |
E |
BLOCK:ZONE1_WALL_3_0_0 |
HIGH PERFORMING PROJECT WALL R-12 |
0.30 |
0.084 |
0.090 |
200.02 |
200.02 |
0.00 |
90.00 |
N |
BLOCK:ZONE1_WALL_4_0_0 |
HIGH PERFORMING PROJECT WALL R-12 |
0.30 |
0.084 |
0.090 |
268.03 |
214.42 |
270.00 |
90.00 |
W |
BLOCK:ZONE1_WALL_5_0_0 |
HIGH PERFORMING PROJECT WALL R-12 |
0.30 |
0.084 |
0.090 |
200.02 |
200.02 |
180.00 |
90.00 |
S |
BLOCK:ZONE1_GROUNDFLOOR_0_0_0 |
PROJECT GROUND FLOOR |
0.40 |
0.056 |
0.059 |
837.58 |
837.58 |
0.00 |
180.00 |
|
BLOCK:ZONE1_ROOF_1_0_0 |
HIGH PERFORMING PROJECT FLAT ROOF R-37 |
0.15 |
0.027 |
0.027 |
837.58 |
837.58 |
180.00 |
0.00 |
|
Opaque Interior
|
Construction |
Reflectance |
U-Factor with Film [Btu/h-ft2-F] |
U-Factor no Film [Btu/h-ft2-F] |
Gross Area [ft2] |
Net Area [ft2] |
Azimuth [deg] |
Tilt [deg] |
Cardinal Direction |
None |
|
|
|
|
|
|
|
|
|
Exterior Fenestration
|
Construction |
Glass Area [ft2] |
Frame Area [ft2] |
Divider Area [ft2] |
Area of One Opening [ft2] |
Area of Multiplied Openings [ft2] |
Glass U-Factor [Btu/h-ft2-F] |
Glass SHGC |
Glass Visible Transmittance |
Frame Conductance [Btu/h-ft2-F] |
Divider Conductance [Btu/h-ft2-F] |
Shade Control |
Parent Surface |
Azimuth [deg] |
Tilt [deg] |
Cardinal Direction |
BLOCK:ZONE1_WALL_2_0_0_0_0_1_WIN |
PROJECT - U-0.55 - 1001 |
23.51 |
2.65 |
0.64 |
26.80 |
53.61 |
0.551 |
0.551 |
0.901 |
1.673 |
1.673 |
No |
BLOCK:ZONE1_WALL_2_0_0 |
90.00 |
90.00 |
E |
BLOCK:ZONE1_WALL_4_0_0_0_0_1_WIN |
PROJECT - U-0.55 - 1001 |
23.51 |
2.65 |
0.64 |
26.80 |
53.61 |
0.551 |
0.551 |
0.901 |
1.673 |
1.673 |
No |
BLOCK:ZONE1_WALL_4_0_0 |
270.00 |
90.00 |
W |
Total or Average |
|
|
|
|
|
107.21 |
0.551 |
0.551 |
0.901 |
|
|
|
|
|
|
|
North Total or Average |
|
|
|
|
|
0.00 |
- |
- |
- |
|
|
|
|
|
|
|
Non-North Total or Average |
|
|
|
|
|
107.21 |
0.551 |
0.551 |
0.901 |
|
|
|
|
|
|
|
Interior Fenestration
|
Construction |
Area of One Opening [ft2] |
Area of Openings [ft2] |
Glass U-Factor [Btu/h-ft2-F] |
Glass SHGC |
Glass Visible Transmittance |
Parent Surface |
Total or Average |
|
|
0.00 |
- |
- |
- |
|
Exterior Door
|
Construction |
U-Factor with Film [Btu/h-ft2-F] |
U-Factor no Film [Btu/h-ft2-F] |
Gross Area [ft2] |
Parent Surface |
None |
|
|
|
|
|
Interior Door
|
Construction |
U-Factor with Film [Btu/h-ft2-F] |
U-Factor no Film [Btu/h-ft2-F] |
Gross Area [ft2] |
Parent Surface |
None |
|
|
|
|
|
Table of Contents
Report: Lighting Summary
For: Entire Facility
Timestamp: 2024-04-11
16:19:26
Interior Lighting
|
Zone |
Lighting Power Density [Btu/h-ft2] |
Zone Area [ft2] |
Total Power [Btu/h] |
End Use Subcategory |
Schedule Name |
Scheduled Hours/Week [hr] |
Hours/Week > 1% [hr] |
Full Load Hours/Week [hr] |
Return Air Fraction |
Conditioned (Y/N) |
Consumption [kWh] |
BLOCK:ZONE1 GENERAL LIGHTING |
BLOCK:ZONE1 |
0.8529 |
837.58 |
714.39 |
General |
RESIDENTIAL LIGHT1 |
64.40 |
168.00 |
64.40 |
0.0000 |
Y |
703.08 |
Interior Lighting Total |
|
0.8529 |
837.58 |
714.39 |
|
|
|
|
|
|
|
703.08 |
Daylighting
|
Zone |
Control Name |
Daylighting Method |
Control Type |
Fraction Controlled |
Lighting Installed in Zone [Btu/h] |
Lighting Controlled [Btu/h] |
None |
|
|
|
|
|
|
|
Exterior Lighting
|
Total Watts |
Astronomical Clock/Schedule |
Schedule Name |
Scheduled Hours/Week [hr] |
Hours/Week > 1% [hr] |
Full Load Hours/Week [hr] |
Consumption [kWh] |
Exterior Lighting Total |
0.00 |
|
|
|
|
|
0.00 |
Table of Contents
Report: Equipment Summary
For: Entire Facility
Timestamp: 2024-04-11
16:19:26
Central Plant
|
Type |
Nominal Capacity [Btu/h] |
Nominal Efficiency [Btuh/Btuh] |
IPLV in SI Units [W/W] |
IPLV in IP Units [Btu/W-h] |
None |
|
|
|
|
|
Cooling Coils
|
Type |
Design Coil Load [Btu/h] |
Nominal Total Capacity [Btu/h] |
Nominal Sensible Capacity [Btu/h] |
Nominal Latent Capacity [Btu/h] |
Nominal Sensible Heat Ratio |
Nominal Efficiency [Btuh/Btuh] |
Nominal Coil UA Value [Btu/h-F] |
Nominal Coil Surface Area [ft2] |
BLOCK:ZONE1 PTAC DX COOLING COIL |
Coil:Cooling:DX:SingleSpeed |
|
43793.72 |
31108.18 |
12685.53 |
0.71 |
2.50 |
|
|
Nominal values are gross at rated conditions, i.e., the supply air fan heat and electric power NOT accounted for.
DX Cooling Coils
|
DX Cooling Coil Type |
Standard Rated Net Cooling Capacity [ton] |
Standard Rated Net COP [Btuh/Btuh] |
EER [Btu/W-h] |
SEER User [Btu/W-h] |
SEER Standard [Btu/W-h] |
IEER [Btu/W-h] |
BLOCK:ZONE1 PTAC DX COOLING COIL |
|
3.5 |
2.24 |
7.64 |
8.13 |
7.69 |
8.11 |
ANSI/AHRI ratings account for supply air fan heat and electric power. SEER User is calculated using user-input PLF curve and cooling coefficient of degradation whereas SEER Standard is calculated using AHRI Std 210/240-2008 default PLF curve and cooling coefficient of degradation.
DX Cooling Coil ASHRAE 127 Standard Ratings Report
|
DX Cooling Coil Type |
Rated Net Cooling Capacity Test A [ton] |
Rated Electric Power Test A [W] |
Rated Net Cooling Capacity Test B [ton] |
Rated Electric Power Test B [W] |
Rated Net Cooling Capacity Test C [ton] |
Rated Electric Power Test C [W] |
Rated Net Cooling Capacity Test D [ton] |
Rated Electric Power Test D [W] |
BLOCK:ZONE1 PTAC DX COOLING COIL |
Coil:Cooling:DX:SingleSpeed |
|
|
|
|
|
|
|
|
DX Heating Coils
|
DX Heating Coil Type |
High Temperature Heating (net) Rating Capacity [Btu/h] |
Low Temperature Heating (net) Rating Capacity [Btu/h] |
HSPF [Btu/W-h] |
Region Number |
None |
|
|
|
|
|
Heating Coils
|
Type |
Design Coil Load [Btu/h] |
Nominal Total Capacity [Btu/h] |
Nominal Efficiency [Btuh/Btuh] |
BLOCK:ZONE1 PTAC HEATING COIL |
Coil:Heating:Electric |
|
33044.24 |
1.00 |
AIR LOOP AHU HEATING COIL |
Coil:Heating:Fuel |
|
32802.12 |
0.75 |
Fans
|
Type |
Total Efficiency [Btuh/Btuh] |
Delta Pressure [psi] |
Max Air Flow Rate [ft3/min] |
Rated Electricity Rate [W] |
Rated Power Per Max Air Flow Rate [W-min/ft3] |
Motor Heat In Air Fraction |
Fan Energy Index |
End Use Subcategory |
Design Day Name for Fan Sizing Peak |
Date/Time for Fan Sizing Peak |
BLOCK:ZONE1 PTAC SUPPLY FAN |
Fan:OnOff |
0.70 |
0.01 |
1127.47 |
76.02 |
0.07 |
1.00 |
4.12 |
General |
SUMMER DESIGN DAY IN BRYANT GEOTHERMAL (01-01:31-12) JUN |
6/15 17:20:00 |
AIR LOOP AHU SUPPLY FAN |
Fan:ConstantVolume |
0.60 |
0.05 |
1127.47 |
304.58 |
0.27 |
1.00 |
2.01 |
General |
WINTER DESIGN DAY IN BRYANT GEOTHERMAL (01-01:31-12) |
1/15 24:00:00 |
Pumps
|
Type |
Control |
Head [psi] |
Water Flow [gal/min] |
Electricity Rate [W] |
Power Per Water Flow Rate [W-min/gal] |
Motor Efficiency [Btuh/Btuh] |
End Use Subcategory |
DHW LOOP SUPPLY PUMP |
Pump:VariableSpeed |
Intermittent |
2.90 |
0.023795 |
0.04 |
1.80 |
0.90 |
General |
Service Water Heating
|
Type |
Storage Volume [ft3] |
Input [Btu/h] |
Thermal Efficiency [Btuh/Btuh] |
Recovery Efficiency [Btuh/Btuh] |
Energy Factor |
DHW LOOP WATER HEATER |
WaterHeater:Mixed |
0.11 |
910.11 |
0.80 |
6.81 |
6.83 |
Table of Contents
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2024-04-11
16:19:26
Zone Sensible Cooling
|
Calculated Design Load [Btu/h] |
User Design Load [Btu/h] |
User Design Load per Area [Btu/h-ft2] |
Calculated Design Air Flow [ft3/min] |
User Design Air Flow [ft3/min] |
Design Day Name |
Date/Time Of Peak {TIMESTAMP} |
Thermostat Setpoint Temperature at Peak Load [F] |
Indoor Temperature at Peak Load [F] |
Indoor Humidity Ratio at Peak Load [lbWater/lbDryAir] |
Outdoor Temperature at Peak Load [F] |
Outdoor Humidity Ratio at Peak Load [lbWater/lbDryAir] |
Minimum Outdoor Air Flow Rate [ft3/min] |
Heat Gain Rate from DOAS [Btu/h] |
BLOCK:ZONE1 |
11527.62 |
13256.77 |
15.83 |
415.009 |
477.260 |
SUMMER DESIGN DAY IN BRYANT GEOTHERMAL (01-01:31-12) JUN |
6/15 17:20:00 |
71.01 |
70.99 |
0.01056 |
85.80 |
0.01451 |
58.652 |
0.00 |
The Design Load is the zone sensible load only. It does not include any system effects or ventilation loads.
Zone Sensible Heating
|
Calculated Design Load [Btu/h] |
User Design Load [Btu/h] |
User Design Load per Area [Btu/h-ft2] |
Calculated Design Air Flow [ft3/min] |
User Design Air Flow [ft3/min] |
Design Day Name |
Date/Time Of Peak {TIMESTAMP} |
Thermostat Setpoint Temperature at Peak Load [F] |
Indoor Temperature at Peak Load [F] |
Indoor Humidity Ratio at Peak Load [lbWater/lbDryAir] |
Outdoor Temperature at Peak Load [F] |
Outdoor Humidity Ratio at Peak Load [lbWater/lbDryAir] |
Minimum Outdoor Air Flow Rate [ft3/min] |
Heat Gain Rate from DOAS [Btu/h] |
BLOCK:ZONE1 |
22923.19 |
28653.99 |
34.21 |
901.976 |
1127.471 |
WINTER DESIGN DAY IN BRYANT GEOTHERMAL (01-01:31-12) |
1/15 24:00:00 |
71.01 |
71.00 |
0.00346 |
0.30 |
0.00082 |
58.652 |
0.00 |
The Design Load is the zone sensible load only. It does not include any system effects or ventilation loads.
System Design Air Flow Rates
|
Calculated cooling [ft3/min] |
User cooling [ft3/min] |
Calculated heating [ft3/min] |
User heating [ft3/min] |
Adjusted cooling [ft3/min] |
Adjusted heating [ft3/min] |
Adjusted main [ft3/min] |
Calculated Heating Air Flow Ratio [] |
User Heating Air Flow Ratio [] |
AIR LOOP |
477.26 |
477.26 |
1127.47 |
1127.47 |
1127.4706 |
1127.4706 |
1127.4706 |
1.0000 |
1.0000 |
Plant Loop Coincident Design Fluid Flow Rate Adjustments
|
Previous Design Volume Flow Rate [ft3/min] |
Algorithm Volume Flow Rate [ft3/min] |
Coincident Design Volume Flow Rate [ft3/min] |
Coincident Size Adjusted |
Peak Sizing Period Name |
Peak Day into Period {TIMESTAMP}[day] |
Peak Hour Of Day {TIMESTAMP}[hr] |
Peak Step Start Minute {TIMESTAMP}[min] |
None |
|
|
|
|
|
|
|
|
Coil Sizing Summary
|
Coil Type |
HVAC Type |
HVAC Name |
Coil Final Gross Total Capacity [Btu/h] |
Coil Final Gross Sensible Capacity [Btu/h] |
Coil Final Reference Air Volume Flow Rate [ft3/min] |
Coil Final Reference Plant Fluid Volume Flow Rate [ft3/min] |
Coil U-value Times Area Value [Btu/h-F] |
Design Day Name at Sensible Ideal Loads Peak |
Date/Time at Sensible Ideal Loads Peak |
Design Day Name at Air Flow Ideal Loads Peak |
Date/Time at Air Flow Ideal Loads Peak |
Coil Total Capacity at Ideal Loads Peak [Btu/h] |
Coil Sensible Capacity at Ideal Loads Peak [Btu/h] |
Coil Air Volume Flow Rate at Ideal Loads Peak [ft3/min] |
Coil Entering Air Drybulb at Ideal Loads Peak [F] |
Coil Entering Air Wetbulb at Ideal Loads Peak [F] |
Coil Entering Air Humidity Ratio at Ideal Loads Peak [lbWater/lbDryAir] |
Coil Leaving Air Drybulb at Ideal Loads Peak [F] |
Coil Leaving Air Wetbulb at Ideal Loads Peak [F] |
Coil Leaving Air Humidity Ratio at Ideal Loads Peak [lbWater/lbDryAir] |
Outdoor Air Drybulb at Ideal Loads Peak [F] |
Outdoor Air Humidity Ratio at Ideal Loads Peak [lbWater/lbDryAir] |
Outdoor Air Wetbulb at Ideal Loads Peak [F] |
Outdoor Air Flow Percentage at Ideal Loads Peak [%] |
Zone Air Drybulb at Ideal Loads Peak [F] |
Zone Air Humidity Ratio at Ideal Loads Peak [lbWater/lbDryAir] |
Zone Air Relative Humidity at Ideal Loads Peak [%] |
Zone Sensible Heat Gain at Ideal Loads Peak [Btu/h] |
Zone Latent Heat Gain at Ideal Loads Peak [Btu/h] |
Coil Total Capacity at Rating Conditions [Btu/h] |
Coil Sensible Capacity at Rating Conditions [Btu/h] |
BLOCK:ZONE1 PTAC DX COOLING COIL |
COIL:COOLING:DX:SINGLESPEED |
ZONEHVAC:PACKAGEDTERMINALAIRCONDITIONER |
BLOCK:ZONE1 PTAC |
43793.717 |
31108.183 |
1127.470603 |
-999. |
-999.00 |
SUMMER DESIGN DAY IN BRYANT GEOTHERMAL (01-01:31-12) JUN |
6/15 17:20:00 |
unknown |
6/15 17:20:00 |
43955.02 |
29759.48 |
1127.470603 |
72.81 |
63.92 |
0.01104444 |
44.78 |
44.78 |
0.00900000 |
85.80 |
0.01450566 |
72.37 |
5.2021 |
70.99 |
0.01055947 |
63.3775 |
13256.77 |
0.00 |
43815.22 |
30700.66 |
BLOCK:ZONE1 PTAC HEATING COIL |
COIL:HEATING:ELECTRIC |
ZONEHVAC:PACKAGEDTERMINALAIRCONDITIONER |
BLOCK:ZONE1 PTAC |
33044.239 |
33044.239 |
-999. |
-999. |
-999.00 |
WINTER DESIGN DAY IN BRYANT GEOTHERMAL (01-01:31-12) |
1/15 24:00:00 |
WINTER DESIGN DAY IN BRYANT GEOTHERMAL (01-01:31-12) |
1/15 24:00:00 |
33044.24 |
33044.24 |
1127.470603 |
67.32 |
48.81 |
0.00332094 |
95.00 |
60.95 |
0.00400000 |
0.30 |
0.00082114 |
0.30 |
5.2021 |
71.00 |
0.00345812 |
20.9880 |
28653.99 |
0.00 |
-999.0 |
-999.0 |
AIR LOOP AHU HEATING COIL |
Coil:Heating:Fuel |
AirLoopHVAC |
AIR LOOP |
32802.115 |
32802.115 |
-999. |
-999. |
-999.00 |
WINTER DESIGN DAY IN BRYANT GEOTHERMAL (01-01:31-12) |
1/15 24:00:00 |
WINTER DESIGN DAY IN BRYANT GEOTHERMAL (01-01:31-12) |
1/15 24:00:00 |
32802.12 |
32802.12 |
1127.470603 |
67.32 |
48.81 |
0.00332094 |
95.00 |
66.79 |
0.00800000 |
0.30 |
0.00082114 |
0.30 |
5.2021 |
71.00 |
0.00345812 |
20.9880 |
22923.19 |
0.00 |
-999.0 |
-999.0 |
Table of Contents
Report: System Summary
For: Entire Facility
Timestamp: 2024-04-11
16:19:26
Economizer
|
High Limit Shutoff Control |
Minimum Outdoor Air [ft3/min] |
Maximum Outdoor Air [ft3/min] |
Return Air Temp Limit |
Return Air Enthalpy Limit |
Outdoor Air Temperature Limit [F] |
Outdoor Air Enthalpy Limit [F] |
None |
|
|
|
|
|
|
|
Demand Controlled Ventilation using Controller:MechanicalVentilation
|
Controller:MechanicalVentilation Name |
Outdoor Air Per Person [ft3/min-person] |
Outdoor Air Per Area [ft3/min-ft2] |
Outdoor Air Per Zone [ft3/min] |
Outdoor Air ACH [ACH] |
Outdoor Air Method |
Outdoor Air Schedule Name |
Air Distribution Effectiveness in Cooling Mode |
Air Distribution Effectiveness in Heating Mode |
Air Distribution Effectiveness Schedule Name |
None |
|
|
|
|
|
|
|
|
|
|
Time Not Comfortable Based on Simple ASHRAE 55-2004
|
Winter Clothes [hr] |
Summer Clothes [hr] |
Summer or Winter Clothes [hr] |
BLOCK:ZONE1 |
4089.67 |
8714.00 |
4088.50 |
Facility |
4089.67 |
8714.00 |
4088.50 |
Aggregated over the RunPeriods for Weather
Time Setpoint Not Met
|
During Heating [hr] |
During Cooling [hr] |
During Occupied Heating [hr] |
During Occupied Cooling [hr] |
BLOCK:ZONE1 |
333.50 |
107.83 |
333.50 |
107.83 |
Facility |
333.50 |
107.83 |
333.50 |
107.83 |
Aggregated over the RunPeriods for Weather
Table of Contents
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2024-04-11
16:19:26
Average Outdoor Air During Occupied Hours
|
Average Number of Occupants |
Nominal Number of Occupants |
Zone Volume [ft3] |
Mechanical Ventilation [ACH] |
Infiltration [ACH] |
AFN Infiltration [ACH] |
Simple Ventilation [ACH] |
BLOCK:ZONE1 |
1.19 |
1.67 |
6700.98 |
0.161 |
1.513 |
0.000 |
0.000 |
Values shown for a single zone without multipliers
Minimum Outdoor Air During Occupied Hours
|
Average Number of Occupants |
Nominal Number of Occupants |
Zone Volume [ft3] |
Mechanical Ventilation [ACH] |
Infiltration [ACH] |
AFN Infiltration [ACH] |
Simple Ventilation [ACH] |
BLOCK:ZONE1 |
1.19 |
1.67 |
6700.98 |
0.000 |
0.026 |
0.000 |
0.000 |
Values shown for a single zone without multipliers
Table of Contents
Report: Object Count Summary
For: Entire Facility
Timestamp: 2024-04-11
16:19:26
Surfaces by Class
|
Total |
Outdoors |
Wall |
4 |
4 |
Floor |
1 |
1 |
Roof |
1 |
1 |
Internal Mass |
0 |
0 |
Building Detached Shading |
0 |
0 |
Fixed Detached Shading |
0 |
0 |
Window |
2 |
2 |
Door |
0 |
0 |
Glass Door |
0 |
0 |
Shading |
0 |
0 |
Overhang |
0 |
0 |
Fin |
0 |
0 |
Tubular Daylighting Device Dome |
0 |
0 |
Tubular Daylighting Device Diffuser |
0 |
0 |
HVAC
|
Count |
HVAC Air Loops |
1 |
Conditioned Zones |
1 |
Unconditioned Zones |
0 |
Supply Plenums |
0 |
Return Plenums |
0 |
Input Fields
|
Count |
IDF Objects |
814 |
Defaulted Fields |
69 |
Fields with Defaults |
1794 |
Autosized Fields |
32 |
Autosizable Fields |
35 |
Autocalculated Fields |
11 |
Autocalculatable Fields |
21 |
Table of Contents
Report: Energy Meters
For: Entire Facility
Timestamp: 2024-04-11
16:19:26
Annual and Peak Values - Electricity
|
Electricity Annual Value [kWh] |
Electricity Minimum Value [W] |
Timestamp of Minimum {TIMESTAMP} |
Electricity Maximum Value [W] |
Timestamp of Maximum {TIMESTAMP} |
Electricity:Facility |
6764.67 |
226.14 |
13-FEB-01:30 |
3406.42 |
15-JUN-17:10 |
Electricity:Building |
2778.72 |
226.13 |
01-JAN-00:10 |
473.19 |
01-JAN-21:10 |
Electricity:Zone:BLOCK:ZONE1 |
2778.72 |
226.13 |
01-JAN-00:10 |
473.19 |
01-JAN-21:10 |
InteriorLights:Electricity |
703.09 |
20.94 |
01-JAN-00:10 |
209.38 |
01-JAN-21:10 |
InteriorLights:Electricity:Zone:BLOCK:ZONE1 |
703.09 |
20.94 |
01-JAN-00:10 |
209.38 |
01-JAN-21:10 |
General:InteriorLights:Electricity |
703.09 |
20.94 |
01-JAN-00:10 |
209.38 |
01-JAN-21:10 |
InteriorEquipment:Electricity |
2075.64 |
205.19 |
01-JAN-00:10 |
293.13 |
01-JAN-17:10 |
InteriorEquipment:Electricity:Zone:BLOCK:ZONE1 |
2075.64 |
205.19 |
01-JAN-00:10 |
293.13 |
01-JAN-17:10 |
General:InteriorEquipment:Electricity |
2075.64 |
205.19 |
01-JAN-00:10 |
293.13 |
01-JAN-17:10 |
ElectricityPurchased:Facility |
6764.67 |
226.14 |
13-FEB-01:30 |
3406.42 |
15-JUN-17:10 |
ElectricityPurchased:Plant |
6764.67 |
226.14 |
13-FEB-01:30 |
3406.42 |
15-JUN-17:10 |
Cogeneration:ElectricityPurchased |
6764.67 |
226.14 |
13-FEB-01:30 |
3406.42 |
15-JUN-17:10 |
General:Cogeneration:ElectricityPurchased |
6764.67 |
226.14 |
13-FEB-01:30 |
3406.42 |
15-JUN-17:10 |
ElectricitySurplusSold:Facility |
0.00 |
0.00 |
01-JAN-00:10 |
0.00 |
01-JAN-00:10 |
ElectricitySurplusSold:Plant |
0.00 |
0.00 |
01-JAN-00:10 |
0.00 |
01-JAN-00:10 |
Cogeneration:ElectricitySurplusSold |
0.00 |
0.00 |
01-JAN-00:10 |
0.00 |
01-JAN-00:10 |
General:Cogeneration:ElectricitySurplusSold |
0.00 |
0.00 |
01-JAN-00:10 |
0.00 |
01-JAN-00:10 |
ElectricityNet:Facility |
6764.67 |
226.14 |
13-FEB-01:30 |
3406.42 |
15-JUN-17:10 |
ElectricityNet:Plant |
6764.67 |
226.14 |
13-FEB-01:30 |
3406.42 |
15-JUN-17:10 |
Cogeneration:ElectricityNet |
6764.67 |
226.14 |
13-FEB-01:30 |
3406.42 |
15-JUN-17:10 |
General:Cogeneration:ElectricityNet |
6764.67 |
226.14 |
13-FEB-01:30 |
3406.42 |
15-JUN-17:10 |
Electricity:HVAC |
3985.67 |
0.00 |
01-JAN-01:10 |
2987.63 |
15-JUN-17:10 |
Fans:Electricity |
1765.46 |
0.00 |
01-JAN-01:10 |
346.84 |
15-JUN-17:10 |
General:Fans:Electricity |
1765.46 |
0.00 |
01-JAN-01:10 |
346.84 |
15-JUN-17:10 |
Heating:Electricity |
0.00 |
0.00 |
01-JAN-00:10 |
0.00 |
01-JAN-00:10 |
General:Heating:Electricity |
0.00 |
0.00 |
01-JAN-00:10 |
0.00 |
01-JAN-00:10 |
Cooling:Electricity |
2220.21 |
0.00 |
01-JAN-00:10 |
2640.79 |
15-JUN-17:10 |
General:Cooling:Electricity |
2220.21 |
0.00 |
01-JAN-00:10 |
2640.79 |
15-JUN-17:10 |
Electricity:Plant |
0.27 |
0.01 |
13-FEB-01:40 |
0.04 |
01-JAN-07:10 |
Pumps:Electricity |
0.27 |
0.01 |
13-FEB-01:40 |
0.04 |
01-JAN-07:10 |
General:Pumps:Electricity |
0.27 |
0.01 |
13-FEB-01:40 |
0.04 |
01-JAN-07:10 |
WaterSystems:Electricity |
0.00 |
0.00 |
01-JAN-00:10 |
0.00 |
01-JAN-00:10 |
Water Heater:WaterSystems:Electricity |
0.00 |
0.00 |
01-JAN-00:10 |
0.00 |
01-JAN-00:10 |
Annual and Peak Values - Natural Gas
|
Natural Gas Annual Value [therm] |
Natural Gas Minimum Value [Btu/h] |
Timestamp of Minimum {TIMESTAMP} |
Natural Gas Maximum Value [Btu/h] |
Timestamp of Maximum {TIMESTAMP} |
NaturalGas:Facility |
682.49 |
200.03 |
01-JAN-02:20 |
41455.60 |
29-JAN-06:10 |
NaturalGas:Building |
20.25 |
200.03 |
01-JAN-00:10 |
285.76 |
01-JAN-17:10 |
NaturalGas:Zone:BLOCK:ZONE1 |
20.25 |
200.03 |
01-JAN-00:10 |
285.76 |
01-JAN-17:10 |
InteriorEquipment:NaturalGas |
20.25 |
200.03 |
01-JAN-00:10 |
285.76 |
01-JAN-17:10 |
InteriorEquipment:NaturalGas:Zone:BLOCK:ZONE1 |
20.25 |
200.03 |
01-JAN-00:10 |
285.76 |
01-JAN-17:10 |
General:InteriorEquipment:NaturalGas |
20.25 |
200.03 |
01-JAN-00:10 |
285.76 |
01-JAN-17:10 |
NaturalGas:HVAC |
583.01 |
0.00 |
01-JAN-01:10 |
40269.67 |
29-JAN-06:10 |
Heating:NaturalGas |
583.01 |
0.00 |
01-JAN-01:10 |
40269.67 |
29-JAN-06:10 |
General:Heating:NaturalGas |
583.01 |
0.00 |
01-JAN-01:10 |
40269.67 |
29-JAN-06:10 |
NaturalGas:Plant |
79.24 |
0.00 |
01-JAN-00:10 |
1340.52 |
01-JAN-22:10 |
WaterSystems:NaturalGas |
79.24 |
0.00 |
01-JAN-00:10 |
1340.52 |
01-JAN-22:10 |
Water Heater:WaterSystems:NaturalGas |
79.24 |
0.00 |
01-JAN-00:10 |
1340.52 |
01-JAN-22:10 |
Annual and Peak Values - Cooling
|
Cooling Annual Value [ton-hrs] |
Cooling Minimum Value [ton] |
Timestamp of Minimum {TIMESTAMP} |
Cooling Maximum Value [ton] |
Timestamp of Maximum {TIMESTAMP} |
None |
|
|
|
|
|
Annual and Peak Values - Water
|
Annual Value [ft3] |
Minimum Value [ft3/min] |
Timestamp of Minimum {TIMESTAMP} |
Maximum Value [ft3/min] |
Timestamp of Maximum {TIMESTAMP} |
Water:Facility |
1226.13 |
0.00 |
02-JAN-01:30 |
0.00 |
12-MAY-07:00 |
Water:Plant |
1226.13 |
0.00 |
02-JAN-01:30 |
0.00 |
12-MAY-07:00 |
WaterSystems:Water |
1226.13 |
0.00 |
02-JAN-01:30 |
0.00 |
12-MAY-07:00 |
General:WaterSystems:Water |
1226.13 |
0.00 |
02-JAN-01:30 |
0.00 |
12-MAY-07:00 |
MainsWater:Facility |
1226.13 |
0.00 |
02-JAN-01:30 |
0.00 |
12-MAY-07:00 |
MainsWater:Plant |
1226.13 |
0.00 |
02-JAN-01:30 |
0.00 |
12-MAY-07:00 |
WaterSystems:MainsWater |
1226.13 |
0.00 |
02-JAN-01:30 |
0.00 |
12-MAY-07:00 |
General:WaterSystems:MainsWater |
1226.13 |
0.00 |
02-JAN-01:30 |
0.00 |
12-MAY-07:00 |
Water Heater:WaterSystems:Water |
0.00 |
0.00 |
01-JAN-00:10 |
0.00 |
01-JAN-00:10 |
Water Heater:WaterSystems:MainsWater |
0.00 |
0.00 |
01-JAN-00:10 |
0.00 |
01-JAN-00:10 |
Annual and Peak Values - Other by Weight/Mass
|
Annual Value [lb] |
Minimum Value [lb/s] |
Timestamp of Minimum {TIMESTAMP} |
Maximum Value [lb/s] |
Timestamp of Maximum {TIMESTAMP} |
Carbon Equivalent:Facility |
0.00 |
0.000 |
01-JAN-00:10 |
0.000 |
01-JAN-00:10 |
CarbonEquivalentEmissions:Carbon Equivalent |
0.00 |
0.000 |
01-JAN-00:10 |
0.000 |
01-JAN-00:10 |
Annual and Peak Values - Other Volumetric
|
Annual Value [ft3] |
Minimum Value [ft3/min] |
Timestamp of Minimum {TIMESTAMP} |
Maximum Value [ft3/min] |
Timestamp of Maximum {TIMESTAMP} |
None |
|
|
|
|
|
Annual and Peak Values - Other Liquid/Gas
|
Annual Value [gal] |
Minimum Value [gal] |
Timestamp of Minimum {TIMESTAMP} |
Maximum Value [gal] |
Timestamp of Maximum {TIMESTAMP} |
None |
|
|
|
|
|
Annual and Peak Values - Other
|
Annual Value [kBtu] |
Minimum Value [Btu/h] |
Timestamp of Minimum {TIMESTAMP} |
Maximum Value [Btu/h] |
Timestamp of Maximum {TIMESTAMP} |
EnergyTransfer:Facility |
121002.00 |
217.52 |
13-AUG-02:20 |
56504.06 |
29-JAN-06:10 |
EnergyTransfer:Building |
51710.48 |
0.00 |
01-JAN-01:10 |
26351.19 |
29-JAN-05:10 |
EnergyTransfer:Zone:BLOCK:ZONE1 |
51710.48 |
0.00 |
01-JAN-01:10 |
26351.19 |
29-JAN-05:10 |
Heating:EnergyTransfer |
41608.67 |
0.00 |
01-JAN-01:10 |
26351.19 |
29-JAN-05:10 |
Heating:EnergyTransfer:Zone:BLOCK:ZONE1 |
41608.67 |
0.00 |
01-JAN-01:10 |
26351.19 |
29-JAN-05:10 |
General:Heating:EnergyTransfer |
41608.67 |
0.00 |
01-JAN-01:10 |
26351.19 |
29-JAN-05:10 |
Cooling:EnergyTransfer |
10101.81 |
0.00 |
01-JAN-00:10 |
11198.97 |
15-JUN-17:00 |
Cooling:EnergyTransfer:Zone:BLOCK:ZONE1 |
10101.81 |
0.00 |
01-JAN-00:10 |
11198.97 |
15-JUN-17:00 |
General:Cooling:EnergyTransfer |
10101.81 |
0.00 |
01-JAN-00:10 |
11198.97 |
15-JUN-17:00 |
EnergyTransfer:HVAC |
63874.79 |
0.00 |
01-JAN-01:10 |
30202.25 |
29-JAN-06:10 |
HeatingCoils:EnergyTransfer |
43725.69 |
0.00 |
01-JAN-01:10 |
30202.25 |
29-JAN-06:10 |
CoolingCoils:EnergyTransfer |
20149.10 |
0.00 |
01-JAN-00:10 |
21471.34 |
15-JUN-17:10 |
EnergyTransfer:Plant |
5416.73 |
217.52 |
13-AUG-02:20 |
976.87 |
26-FEB-20:10 |
WaterSystems:EnergyTransfer |
5416.73 |
217.52 |
13-AUG-02:20 |
976.87 |
26-FEB-20:10 |
General:WaterSystems:EnergyTransfer |
5416.73 |
217.52 |
13-AUG-02:20 |
976.87 |
26-FEB-20:10 |
PlantLoopHeatingDemand:Facility |
5416.82 |
217.52 |
13-AUG-02:20 |
976.97 |
26-FEB-20:10 |
PlantLoopHeatingDemand:Plant |
5416.82 |
217.52 |
13-AUG-02:20 |
976.97 |
26-FEB-20:10 |
WaterSystems:PlantLoopHeatingDemand |
5416.82 |
217.52 |
13-AUG-02:20 |
976.97 |
26-FEB-20:10 |
General:WaterSystems:PlantLoopHeatingDemand |
5416.82 |
217.52 |
13-AUG-02:20 |
976.97 |
26-FEB-20:10 |
Water Heater:WaterSystems:PlantLoopHeatingDemand |
0.00 |
0.00 |
01-JAN-00:10 |
0.00 |
01-JAN-00:10 |
Table of Contents
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2024-04-11
16:19:26
Annual Building Sensible Heat Gain Components
|
HVAC Zone Eq & Other Sensible Air Heating [kBtu] |
HVAC Zone Eq & Other Sensible Air Cooling [ton-hrs] |
HVAC Terminal Unit Sensible Air Heating [kBtu] |
HVAC Terminal Unit Sensible Air Cooling [ton-hrs] |
HVAC Input Heated Surface Heating [kBtu] |
HVAC Input Cooled Surface Cooling [ton-hrs] |
People Sensible Heat Addition [kBtu] |
Lights Sensible Heat Addition [kBtu] |
Equipment Sensible Heat Addition [kBtu] |
Window Heat Addition [kBtu] |
Interzone Air Transfer Heat Addition [kBtu] |
Infiltration Heat Addition [kBtu] |
Opaque Surface Conduction and Other Heat Addition [kBtu] |
Equipment Sensible Heat Removal [kBtu] |
Window Heat Removal [kBtu] |
Interzone Air Transfer Heat Removal [kBtu] |
Infiltration Heat Removal [kBtu] |
Opaque Surface Conduction and Other Heat Removal [kBtu] |
BLOCK:ZONE1 |
0.000 |
-1175.98 |
45628.084 |
0.000 |
0.000 |
0.000 |
2839.294 |
2400.635 |
9111.975 |
10369.078 |
0.000 |
1494.068 |
0.263 |
0.000 |
-6608.41 |
0.000 |
-36814.32 |
-14299.23 |
Total Facility |
0.000 |
-1175.98 |
45628.084 |
0.000 |
0.000 |
0.000 |
2839.294 |
2400.635 |
9111.975 |
10369.078 |
0.000 |
1494.068 |
0.263 |
0.000 |
-6608.41 |
0.000 |
-36814.32 |
-14299.23 |
Peak Cooling Sensible Heat Gain Components
|
Time of Peak {TIMESTAMP} |
HVAC Zone Eq & Other Sensible Air Heating [Btu/h] |
HVAC Zone Eq & Other Sensible Air Cooling [ton] |
HVAC Terminal Unit Sensible Air Heating [Btu/h] |
HVAC Terminal Unit Sensible Air Cooling [ton] |
HVAC Input Heated Surface Heating [Btu/h] |
HVAC Input Cooled Surface Cooling [ton] |
People Sensible Heat Addition [Btu/h] |
Lights Sensible Heat Addition [Btu/h] |
Equipment Sensible Heat Addition [Btu/h] |
Window Heat Addition [Btu/h] |
Interzone Air Transfer Heat Addition [Btu/h] |
Infiltration Heat Addition [Btu/h] |
Opaque Surface Conduction and Other Heat Addition [Btu/h] |
Equipment Sensible Heat Removal [Btu/h] |
Window Heat Removal [Btu/h] |
Interzone Air Transfer Heat Removal [Btu/h] |
Infiltration Heat Removal [Btu/h] |
Opaque Surface Conduction and Other Heat Removal [Btu/h] |
BLOCK:ZONE1 |
22-JUN-08:63 |
0.00 |
-1.0 |
0.00 |
0.00 |
0.00 |
0.00 |
217.47 |
285.76 |
1028.73 |
7045.47 |
0.00 |
1694.71 |
2178.86 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Total Facility |
22-JUN-08:63 |
0.00 |
-1.0 |
0.00 |
0.00 |
0.00 |
0.00 |
217.47 |
285.76 |
1028.73 |
7045.47 |
0.00 |
1694.71 |
2178.86 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Peak Heating Sensible Heat Gain Components
|
Time of Peak {TIMESTAMP} |
HVAC Zone Eq & Other Sensible Air Heating [Btu/h] |
HVAC Zone Eq & Other Sensible Air Cooling [ton] |
HVAC Terminal Unit Sensible Air Heating [Btu/h] |
HVAC Terminal Unit Sensible Air Cooling [ton] |
HVAC Input Heated Surface Heating [Btu/h] |
HVAC Input Cooled Surface Cooling [ton] |
People Sensible Heat Addition [Btu/h] |
Lights Sensible Heat Addition [Btu/h] |
Equipment Sensible Heat Addition [Btu/h] |
Window Heat Addition [Btu/h] |
Interzone Air Transfer Heat Addition [Btu/h] |
Infiltration Heat Addition [Btu/h] |
Opaque Surface Conduction and Other Heat Addition [Btu/h] |
Equipment Sensible Heat Removal [Btu/h] |
Window Heat Removal [Btu/h] |
Interzone Air Transfer Heat Removal [Btu/h] |
Infiltration Heat Removal [Btu/h] |
Opaque Surface Conduction and Other Heat Removal [Btu/h] |
BLOCK:ZONE1 |
29-JAN-08:03 |
0.00 |
0.00 |
33989.69 |
0.00 |
0.00 |
0.00 |
226.84 |
285.76 |
1028.73 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
-459.6 |
0.00 |
-15339.9 |
-19731.4 |
Total Facility |
29-JAN-08:03 |
0.00 |
0.00 |
33989.69 |
0.00 |
0.00 |
0.00 |
226.84 |
285.76 |
1028.73 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
-459.6 |
0.00 |
-15339.9 |
-19731.4 |
Table of Contents
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2024-04-11
16:19:26
System Ventilation Requirements for Cooling
|
Sum of Zone Primary Air Flow - Vpz-sum [ft3/min] |
System Population - Ps |
Sum of Zone Population - Pz-sum |
Occupant Diversity - D |
Uncorrected Outdoor Air Intake Airflow - Vou [ft3/min] |
System Primary Airflow - Vps [ft3/min] |
Average Outdoor Air Fraction - Xs |
System Ventilation Efficiency - Ev |
Outdoor Air Intake Flow - Vot [ft3/min] |
Percent Outdoor Air - %OA |
Environment Name of Peak System Population - Ps |
Date and Time of Last Peak System Population - Ps |
AIR LOOP |
1127.4706 |
0.0000 |
1.6750 |
1.0000 |
58.6523 |
1127.4706 |
1.0000 |
1.0000 |
58.6523 |
0.0520 |
|
|
System Ventilation Requirements for Heating
|
Sum of Zone Primary Air Flow - Vpz-sum [ft3/min] |
System Population - Ps |
Sum of Zone Population - Pz-sum |
Occupant Diversity - D |
Uncorrected Outdoor Air Intake Airflow - Vou [ft3/min] |
System Primary Airflow - Vps [ft3/min] |
Average Outdoor Air Fraction - Xs |
System Ventilation Efficiency - Ev |
Outdoor Air Intake Flow Vot [ft3/min] |
Percent Outdoor Air - %OA |
Environment Name of Peak System Population - Ps |
Date and Time of Last Peak System Population - Ps |
AIR LOOP |
1127.4706 |
0.0000 |
1.6750 |
1.0000 |
58.6523 |
1127.4706 |
0.0520 |
1.0000 |
58.6523 |
0.0520 |
|
|
Zone Ventilation Parameters
|
AirLoop Name |
People Outdoor Air Rate - Rp [ft3/min-person] |
Zone Population - Pz |
Area Outdoor Air Rate - Ra [ft3/min-ft2] |
Zone Floor Area - Az [ft2] |
Breathing Zone Outdoor Airflow - Vbz [ft3/min] |
Cooling Zone Air Distribution Effectiveness - Ez-clg |
Cooling Zone Outdoor Airflow - Voz-clg [ft3/min] |
Heating Zone Air Distribution Effectiveness - Ez-htg |
Heating Zone Outdoor Airflow - Voz-htg [ft3/min] |
BLOCK:ZONE1 |
AIR LOOP |
4.999999 |
1.6750 |
0.060039 |
837.58 |
58.6523 |
1.0000 |
58.6523 |
1.000 |
58.6523 |
System Ventilation Parameters
|
People Outdoor Air Rate - Rp [ft3/min-person] |
Sum of Zone Population - Pz-sum |
Area Outdoor Air Rate - Ra [ft3/min-ft2] |
Sum of Zone Floor Area - Az-sum [ft2] |
Breathing Zone Outdoor Airflow - Vbz [ft3/min] |
Cooling Zone Outdoor Airflow - Voz-clg [ft3/min] |
Heating Zone Outdoor Airflow - Voz-htg [ft3/min] |
AIR LOOP |
4.999999 |
1.67 |
0.060039 |
837.5818 |
58.6523 |
58.6523 |
58.6523 |
Zone Ventilation Calculations for Cooling Design
|
AirLoop Name |
Box Type |
Zone Primary Airflow - Vpz [ft3/min] |
Zone Discharge Airflow - Vdz [ft3/min] |
Minimum Zone Primary Airflow - Vpz-min [ft3/min] |
Zone Outdoor Airflow Cooling - Voz-clg [ft3/min] |
Primary Outdoor Air Fraction - Zpz |
Primary Air Fraction - Ep |
Secondary Recirculation Fraction- Er |
Supply Air Fraction- Fa |
Mixed Air Fraction - Fb |
Outdoor Air Fraction - Fc |
Zone Ventilation Efficiency - Evz |
BLOCK:ZONE1 |
AIR LOOP |
AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT |
1127.4706 |
1127.4706 |
1127.4706 |
58.6523 |
0.0000 |
1.0000 |
0.0000 |
0.0000 |
0.0000 |
0.0000 |
1.0000 |
System Ventilation Calculations for Cooling Design
|
Sum of Zone Primary Airflow - Vpz-sum [ft3/min] |
System Primary Airflow - Vps [ft3/min] |
Sum of Zone Discharge Airflow - Vdz-sum [ft3/min] |
Sum of Min Zone Primary Airflow - Vpz-min [ft3/min] |
Zone Outdoor Airflow Cooling - Voz-clg [ft3/min] |
Zone Ventilation Efficiency - Evz-min |
AIR LOOP |
1127.4706 |
1127.4706 |
1127.4706 |
1127.4706 |
58.6523 |
1.0000 |
Zone Ventilation Calculations for Heating Design
|
AirLoop Name |
Box Type |
Zone Primary Airflow - Vpz [ft3/min] |
Zone Discharge Airflow - Vdz [ft3/min] |
Minimum Zone Primary Airflow - Vpz-min [ft3/min] |
Zone Outdoor Airflow Heating - Voz-htg [ft3/min] |
Primary Outdoor Air Fraction - Zpz |
Primary Air Fraction - Ep |
Secondary Recirculation Fraction- Er |
Supply Air Fraction- Fa |
Mixed Air Fraction - Fb |
Outdoor Air Fraction - Fc |
Zone Ventilation Efficiency - Evz |
BLOCK:ZONE1 |
AIR LOOP |
AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT |
1127.4706 |
1127.4706 |
1127.4706 |
58.6523 |
0.0520 |
1.0000 |
0.0000 |
0.0000 |
0.0000 |
0.0000 |
1.0000 |
System Ventilation Calculations for Heating Design
|
Sum of Zone Primary Airflow - Vpz-sum [ft3/min] |
System Primary Airflow - Vps [ft3/min] |
Sum of Zone Discharge Airflow - Vdz-sum [ft3/min] |
Sum of Min Zone Primary Airflow - Vpz-min [ft3/min] |
Zone Outdoor Airflow Heating - Voz-htg [ft3/min] |
Zone Ventilation Efficiency - Evz-min |
AIR LOOP |
1127.4706 |
1127.4706 |
1127.4706 |
1127.4706 |
58.6523 |
1.0000 |
Table of Contents
Report: LEED Summary
For: Entire Facility
Timestamp: 2024-04-11
16:19:26
Sec1.1A-General Information
|
Data |
Weather File |
BRYANT GEOTHERMAL (01-01:31-12) ** MI_ANN-ARBOR-MUNI-AP - USA Custom-725374 WMO#=725374 |
Total gross floor area [ft2] |
837.58 |
Principal Heating Source |
Natural Gas |
EAp2-1. Space Usage Type
|
Space Area [ft2] |
Regularly Occupied Area [ft2] |
Unconditioned Area [ft2] |
Typical Hours/Week in Operation [hr/wk] |
BLOCK:ZONE1 |
837.58 |
837.58 |
0.00 |
168.00 |
Totals |
837.58 |
837.58 |
0.00 |
|
EAp2-2. Advisory Messages
|
Data |
Number of hours heating loads not met |
333.50 |
Number of hours cooling loads not met |
107.83 |
Number of hours not met |
441.33 |
EAp2-3. Energy Type Summary
|
Utility Rate |
Virtual Rate [$/unit energy] |
Units of Energy |
Units of Demand |
None |
|
|
|
|
EAp2-4/5. Performance Rating Method Compliance
|
Electricity Energy Use [kWh] |
Electricity Demand [W] |
Natural Gas Energy Use [therm] |
Natural Gas Demand [Btu/h] |
Gasoline Use [therm] |
Gasoline Demand [Btu/h] |
Diesel Use [kBtu] |
Diesel Demand [Btu/h] |
Coal Use [kBtu] |
Coal Demand [Btu/h] |
Fuel Oil No 1 Use [kBtu] |
Fuel Oil No 1 Demand [Btu/h] |
Fuel Oil No 2 Use [kBtu] |
Fuel Oil No 2 Demand [Btu/h] |
Propane Use [kBtu] |
Propane Demand [Btu/h] |
Other Fuel 1 Use [kBtu] |
Other Fuel 1 Demand [Btu/h] |
Other Fuel 2 Use [kBtu] |
Other Fuel 2 Demand [Btu/h] |
District Cooling Use [ton-hrs] |
District Cooling Demand [ton] |
District Heating Use [kBtu] |
District Heating Demand [Btu/h] |
Heating -- General |
0.00 |
0.00 |
583.01 |
40269.67 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Cooling -- General |
2220.21 |
2640.79 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Interior Lighting -- General |
703.09 |
209.38 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Exterior Lighting -- Not Subdivided |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Interior Equipment -- General |
2075.64 |
293.13 |
20.25 |
285.76 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Exterior Equipment -- Not Subdivided |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Fans -- General |
1765.46 |
346.84 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Pumps -- General |
0.27 |
0.04 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Heat Rejection -- Not Subdivided |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Humidification -- Not Subdivided |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Heat Recovery -- Not Subdivided |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Water Systems -- General |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Water Systems -- Water Heater |
0.00 |
0.00 |
79.24 |
1340.52 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Refrigeration -- Not Subdivided |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
Generators -- General |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
0.00 |
EAp2-6. Energy Use Summary
|
Process Subtotal [kBtu] |
Total Energy Use [kBtu] |
Electricity |
7087.09 |
23097.42 |
Natural Gas |
2024.88 |
68249.30 |
Additional |
0.00 |
0.00 |
Total |
9111.97 |
91346.72 |
EAp2-7. Energy Cost Summary
|
Process Subtotal [$] |
Total Energy Cost [$] |
Electricity |
0.00 |
|
Natural Gas |
0.00 |
|
Additional |
0.00 |
|
Total |
0.00 |
|
Process energy cost based on ratio of process to total energy.
L-1. Renewable Energy Source Summary
|
Rated Capacity [kW] |
Annual Energy Generated [kBtu] |
Photovoltaic |
0.00 |
0.00 |
Wind |
0.00 |
0.00 |
EAp2-17a. Energy Use Intensity - Electricity
|
Electricty [kWh/ft2] |
Interior Lighting (All) |
0.84 |
Space Heating |
0.00 |
Space Cooling |
2.65 |
Fans (All) |
2.11 |
Service Water Heating |
0.00 |
Receptacle Equipment |
2.48 |
Miscellaneous (All) |
8.08 |
Subtotal |
8.08 |
EAp2-17b. Energy Use Intensity - Natural Gas
|
Natural Gas [kWh/ft2] |
Space Heating |
20.39 |
Service Water Heating |
2.77 |
Miscellaneous (All) |
23.86 |
Subtotal |
23.86 |
EAp2-17c. Energy Use Intensity - Additional
|
Additional [kBtu/ft2] |
Subtotal |
0.00 |
Miscellaneous |
0.00 |
EAp2-18. End Use Percentage
|
Percent [%] |
Interior Lighting (All) |
2.63 |
Space Heating |
63.82 |
Space Cooling |
8.30 |
Fans (All) |
6.60 |
Service Water Heating |
8.67 |
Receptacle Equipment |
9.98 |
Miscellaneous |
0.00 |
Schedules-Equivalent Full Load Hours (Schedule Type=Fraction)
|
Equivalent Full Load Hours of Operation Per Year [hr] |
Hours > 1% [hr] |
RESIDENTIAL OCC |
6119. |
8760. |
COOLING FRACTION SCHEDULE |
8760. |
8760. |
HEATING FRACTION SCHEDULE |
8760. |
8760. |
HVAC AVAIL 6:00 - 8:00 18:00 - 22:00 EVERYDAY |
2190. |
2190. |
RESIDENTIAL PLUG |
7081. |
8760. |
RESIDENTIAL LIGHT1 |
3358. |
8760. |
RESIDENTIAL DHW |
6424. |
8760. |
SUMMER (NORTHERN HEMISPHERE) - EDIT |
4752. |
4752. |
Schedules-SetPoints (Schedule Type=Temperature)
|
First Object Used |
Month Assumed |
11am First Wednesday [F] |
Days with Same 11am Value |
11pm First Wednesday [F] |
Days with Same 11pm Value |
BLOCK:ZONE1 HEATING SETPOINT SCHEDULE |
BLOCK:ZONE1 DUAL SP |
January |
69.01 |
365 |
69.01 |
365 |
BLOCK:ZONE1 COOLING SETPOINT SCHEDULE |
BLOCK:ZONE1 DUAL SP |
July |
71.01 |
365 |
71.01 |
365 |