Search GDR Data
Showing results 1 - 25 of 81.
Show
results per page.
Order by:
Available Now:
Topic
Technologies
Demonstration Sites
Data Type
The dataset includes data collected during an extended circulation test conducted at the Utah FORGE site between August 8 and September 5, 2024. It provides uncorrected, raw digital data from the test, along with calibration information and a final report detailing the test proced...
Includes data for measured inert tracer breakthrough curves first reported in Hawkins (2020) (Water Resources Research). In addition, this submission includes the production well temperature measurements first reported in Hawkins et al. (2017a) (Water Resources Research, volume 53...
These data and test descriptions comprise a chilled circulation test conducted at the 164' fracture in the EGS Collab Experiment 1 testbed on the 4850 ft level of the Sanford Underground Research Facility. Descriptions of the meta data, design drawings for the flow testing system,...
Scripts and data acquired at the Mirror Lake Research Site, cited by the article submitted to Water Resources Research:
Distributed Acoustic Sensing (DAS) as a Distributed Hydraulic Sensor in Fractured Bedrock
M. W. Becker(1), T. I. Coleman(2), and C. C. Ciervo(1)
1 California St...
This dataset comprises field logging data collected during chemical-based tool deployments at the Utah FORGE geothermal site, specifically at monitoring well 58-32 and production well 16B(78)-32. Data acquisition occurred during the Summer 2024 circulation testing campaign, with t...
Included here are Distributed Acoustic Sensing (DAS) data collected by the horizontal DAS array at Brady's Hot Springs Geothermal Field. The system recorded this data during an M 2.3 explosion at the Nevada Test Site (NTS), which is located approximately 400km southeast of the fie...
Pressure data from a phreatic aquifer was collected in the summer of 2013 during Multi-frequency Oscillatory Hydraulic Tomography pumping tests. All tests were performed at the Boise Hydrogeophysical Research Site. The data will be inverted using a fast steady-periodic adjoint-bas...
This file contains additional data for this test (hydroshear test 3.2). In this test a sample of granite with a pre-cut (man made fracture) is confined, heated and differential stress is applied. The max temperature in this this system development test is 95C. More test details ca...
Data here has been "pre-processed" and "analyzed" from the raw data submitted to the GDR previously (raw data files found at http://gdr.openei.org/submissions/479. doi:10.15121/1176944 after 30 September 2017). First, we submit .mat files which are the "pre-processed" data (must h...
This dataset consists of all of the pressure pumping data for Utah FORGE Well16A78-32 fracturing stages, Well 16B78-32 fracturing stages, and a 9-hour circulation test which took place after all of the frac plugs were drilled out. Fracturing in the wells took place in stages from ...
This data submission includes the raw time-lapse ERT (electrical resistivity tomography) monitoring data, flow system data, operator logs, E4D (https://e4d.pnnl.gov) inversion files, and metadata necessary to reproduce the 4D ERT inversion for the Oct. 24 through Nov. 7 2018 post-...
This dataset encompasses the collected data and associated reports from the low-rate injection circulation test conducted on wells 16A(78)-32 and 16B(78)-32 in July 2023 at Utah FORGE. It includes comprehensive raw circulation data, captured by Pason and Schlumberger (SLB). The da...
Directional Cooling-Induced Fracturing (DCIF) experiments were conducted on three rectangular Westerly granite blocks (width=depth=4.0", height=2.0") which were preheated to 200, 400, and 600 degree C to induce damage (microcracks) with varying degrees. Liquid nitrogen was poured...
This dataset contains experimental measurements of fluid flow and pressure behavior during fracture conductivity tests in granite core samples. The tests were designed to evaluate various ionic and nonionic fluids, including BMiMBr, HPyBF4, HPyBr, an oil-based fluid (OBF-1), and a...
Laboratory experimental data on saw-cut interface of Westerly Granite and Utah Forge granitoid rocks. Experiments include velocity-stepping and fluid pressure stepping experiments. Mechanical data from 3 ISCO pumps connected to a Temco pressure vessel measure axial, confining and ...
These data and test descriptions are from a set of primarily tensile hydraulic-fracture stimulations in wells E2-TC and E2-TU and a subsequent chilled water circulation test conducted by injecting in well E2-TU on the 4100 level of the Sandford Underground Research Facility (SURF)...
Included are datasets from wellbore breakout experiments conducted under triaxial conditions with varying fluid and temperature environments. This dataset serves as one of the experimental reports for the Role of Fluid and Temperature in Fracture Mechanics and Coupled Thermo-Hydro...
This file contains unprocessed drilling data tests on Sierra White Granite (SWG) using two new PDC bits. The tests were conducted at Sandia National Laboratories (SNL) in the Hard Rock Drilling Facility (HRDF). The collected data includes ROP data at rotational speeds of 80, 120, ...
Included are a report and data from triaxial shear tests on simulated Sierra White fault gouge and a borehole stimulation experiment. This serves as a progress report for the Role of Fluid and Temperature in Fracture Mechanics and Coupled Thermo-Hydro-Mechanical-Chemical (THMC) P...
This dataset contains temperature, conductivity, and pressure data collected from a geothermal test well in Seward, Alaska, from October 31, 2023, through May 14, 2024. The data from the sensors are used to assess the potential for geothermal heat exchange along the shoreline of t...
This dataset provides a set of experimental data on the performance of lost circulation materials (LCMs) used in geothermal drilling operations. It includes results from four distinct tests: thermal degradation, viscosity measurements, compression tests, and high-temperature flow ...
This dataset contains experimental data from fluid injection experiments conducted to investigate the influence of temperature on fracture seismicity. The experiments were performed on granite samples from Utah FORGE. The samples were prepared with a 30-degree inclined fracture an...
This dataset contains results from laboratory direct shear experiments performed on tension-induced fractures in Sierra White granite under saturated conditions at target temperatures of 50 C and 100 C. The data were collected using a custom water-pressurized chamber equipped with...
This dataset contains trace element concentrations from fluid samples collected during the August-September 2024 circulation test at Utah FORGE. Samples were taken from injection well 16A(78)-32, production well 16B(78)-32, and monitoring well 58-32 on four dates between August 16...
These are production logging tests (PLT) results from Halliburton collected during the nine hour circulation test performed at Utah FORGE on April 27th, 2024. The circulation test involved injecting into well 16A(78)-32 and producing out of well 16B(78)-32) and was carried out af...
Google Map