Search GDR Data
Showing results 1 - 25 of 66.
Show
results per page.
Order by:
Available Now:
Topic
Technologies
Demonstration Sites
Data Type
Images of the Stripa Granite core before and after the fracture sustainability test. Photos of fracture faces of Stripa Granite core.
This is a report from Metarock Laboratories on the thermal properties of Utah FORGE wells 16A(78)-32 & 58-32 granite. The report includes pictures of core samples, core details for the samples (where the sample was taken and the size of the sample), sample thermal expansion test r...
This is a presentaiton from Metarock Laboratories on the thermal properties of Utah FORGE well 58-32 granite core. The presentation includes pictures of core samples, core details for the samples (sample depths and size), sample thermal expansion test results, and radial velocity ...
This dataset includes an Excel file with the results of B-value tests to determine the magnitude of the back pressure required for full saturation of Sierra White granite samples. Test were conducted on cylindrical rock specimens of Sierra White granite in a custom water pressuriz...
This dataset includes an Excel file with the results of direct shear tests to investigate the mechanical and geophysical response of saturated joints. Tests were conducted on induced tension-fractured Sierra White granite joints in a custom water pressurized chamber. The preparati...
Spreadsheet containing the raw measured data, calibrated data, and brief explanation of data for Test1 Stripa Granite Geomechanical/Geochemical Test. Stress on fracture ~20.7 MPa.
This folder contains X-ray CT images and an explanation related to the shear induced permeability testing of Stripa granite
Data includes Directional Cooling-Induced Fracturing (DCIF) testing data using westerly granite blocks. This submission includes data from two samples of westerly granite, lab sample 7 and 8. Files contain stress, temperature and acoustic emission data acquired during polyaxial, l...
A set of triaxial tests with sandstone, limestone, and granite samples was conducted to measure fluid chemistry before, during, and after rock fracture. The dataset here includes: 1) five triaxial test data files (xlxs), 2) one file containing the measured test tube volumes for th...
Laboratory slide-hold-slide tests were conducted in a conventional triaxial deformation configuration on 1-inch diameter cylindrical cores of Westerly granite bisected by a sawcut oriented at 30 degrees from vertical. Tests were conducted at a constant confining pressure of 30 MPa...
Submission includes data from laboratory slide-hold-slide tests, combined with flow through tests, conducted on Westerly granite with 30 degree sawcut. Tests were conducted with a constant confining pressure of 30 MPa with an average pore pressure of 10 MPa at temperatures of 23 a...
This dataset contains results from laboratory direct shear experiments performed on tension-induced fractures in Sierra White granite under saturated conditions at target temperatures of 50 C and 100 C. The data were collected using a custom water-pressurized chamber equipped with...
Geologic map associated with the Nevada Play Fairway project. Includes Sinter and Tufa location, slip and dilation tendency, Quaternary faults, and LiDAR.
This data is associated with the Nevada Play Fairway project and contains the entire package of LiDAR data for Granite Springs Valley.
In addition to the foam data that were obtained from literature and that were collected from the current study, simulation data was also generated from finite element analysis (FEA) conducted in this study using COMSOL Multiphysics software. The FEA models were built to simulate t...
As part of the shear-induced permeability test of Brady well BCH-03, Desert Peak well DP 35-13, and Stripa granite samples, the three post-test (reacted) rock samples were examined using a Scanning Electron Microscope (SEM). The SEM images of the core and elemental analysis are in...
Included are a report and data from triaxial shear tests on simulated Sierra White fault gouge and a borehole stimulation experiment. This serves as a progress report for the Role of Fluid and Temperature in Fracture Mechanics and Coupled Thermo-Hydro-Mechanical-Chemical (THMC) P...
This dataset contains results from a pump and probe experiment conducted on a mated fracture Westerly Granite sample with a diameter of 1 inch and a height of 2 7/8 inches. The experiment was performed within an aluminum triaxial pressure vessel (TEMCO) to investigate the non-line...
Directional Cooling-Induced Fracturing (DCIF) experiments were conducted on rectangular Westerly granite blocks (width=depth=4.0", height=2.0"). Liquid nitrogen was poured in a small, 1"-diameter copper cup attached to the top of the sample, and the resulting acoustic emissions (A...
All raw data for new data acquired, key grids such as CBA and horizontal derivative, acquisition report, and depth models. This gravity data is associated with the Nevada Play Fairway project.
This dataset includes results of direct shear tests to investigate the mechanical and geophysical response of dry and saturated fractures in Indiana limestone and Sierra White granite. Direct shear tests were performed on tensile-induced fractures in Indiana limestone and Sierra W...
Directional Cooling-Induced Fracturing (DCIF) experiments were conducted on a short, cylindrical sample of Westerly granite (diameter = 4 inches, height ~ 2 inches). Liquid nitrogen was poured in a copper cup attached to the top of the sample, and the resulting acoustic emissions ...
This submission includes a methods report and an accompanying Excel dataset documenting temperature-dependent Mode-I fracture toughness (KIC) measurements for Utah FORGE granite obtained using semi-circular bending (SCB) tests in accordance with the ISRM Suggested Method. Testing ...
Directional Cooling-Induced Fracturing (DCIF) experiments were conducted on three rectangular Westerly granite blocks (width=depth=4.0", height=2.0") which were preheated to 200, 400, and 600 degree C to induce damage (microcracks) with varying degrees. Liquid nitrogen was poured...
This dataset contains results from a pump and probe experiment conducted on an intact Westerly Granite sample with a diameter of 1 inch and a height of 1 3/8 inches. The experiment was performed within an aluminum triaxial pressure vessel (TEMCO) to investigate the non-linear acou...
Google Map