Utah FORGE 3-2535: Report on Borehole EM Data Collection and Imaging with the VEMP Field System

Publicly accessible License 

This report outlines electromagnetic field measurements that were made after stimulation at Utah FORGE in May of 2024. The measurements involved lowering an electrode to ~3500' in well 16A to energize the steel casing as part of the electric source, with the return electrode located on the surface approximately 1km to the west. Three component magnetic field measurements were made with the VEMP tool in well 78-32B starting at just below the casing shoe in the open hole and moving upward at 100m increments. Due to noise in the system and other problems, only vertical field measurements were completed over the whole interval.

Citation Formats

Lawrence Berkeley National Laboratory. (2024). Utah FORGE 3-2535: Report on Borehole EM Data Collection and Imaging with the VEMP Field System [data set]. Retrieved from https://gdr.openei.org/submissions/1643.
Export Citation to RIS
Alumbaugh, David, Wilt, Michael, and NIchols, Edward. Utah FORGE 3-2535: Report on Borehole EM Data Collection and Imaging with the VEMP Field System. United States: N.p., 05 Sep, 2024. Web. https://gdr.openei.org/submissions/1643.
Alumbaugh, David, Wilt, Michael, & NIchols, Edward. Utah FORGE 3-2535: Report on Borehole EM Data Collection and Imaging with the VEMP Field System. United States. https://gdr.openei.org/submissions/1643
Alumbaugh, David, Wilt, Michael, and NIchols, Edward. 2024. "Utah FORGE 3-2535: Report on Borehole EM Data Collection and Imaging with the VEMP Field System". United States. https://gdr.openei.org/submissions/1643.
@div{oedi_1643, title = {Utah FORGE 3-2535: Report on Borehole EM Data Collection and Imaging with the VEMP Field System}, author = {Alumbaugh, David, Wilt, Michael, and NIchols, Edward.}, abstractNote = {This report outlines electromagnetic field measurements that were made after stimulation at Utah FORGE in May of 2024. The measurements involved lowering an electrode to ~3500' in well 16A to energize the steel casing as part of the electric source, with the return electrode located on the surface approximately 1km to the west. Three component magnetic field measurements were made with the VEMP tool in well 78-32B starting at just below the casing shoe in the open hole and moving upward at 100m increments. Due to noise in the system and other problems, only vertical field measurements were completed over the whole interval.}, doi = {}, url = {https://gdr.openei.org/submissions/1643}, journal = {}, number = , volume = , place = {United States}, year = {2024}, month = {09}}

Details

Data from Sep 5, 2024

Last updated Sep 10, 2024

Submitted Sep 5, 2024

Organization

Lawrence Berkeley National Laboratory

Contact

David Alumbaugh

510.717.7179

Authors

David Alumbaugh

Lawrence Berkeley National Laboratory

Michael Wilt

Lawrence Berkeley National Laboratory

Edward NIchols

Lawrence Berkeley National Laboratory

DOE Project Details

Project Name Utah FORGE

Project Lead Lauren Boyd

Project Number EE0007080

Share

Submission Downloads