Laboratory Evaluation of EGS Shear Stimulation-Test 001

Publicly accessible License 

This is the results of an initial setup-shakedon test in order to develop the plumbing system for this test design. a cylinder of granite with offset holes was jacketed and subjected to confining pressure and low temperature (85C) and pore water pressure. Flow through the sample was developed at different test stages.

Citation Formats

TY - DATA AB - This is the results of an initial setup-shakedon test in order to develop the plumbing system for this test design. a cylinder of granite with offset holes was jacketed and subjected to confining pressure and low temperature (85C) and pore water pressure. Flow through the sample was developed at different test stages. AU - Bauer, Steve DB - Geothermal Data Repository DP - Open EI | National Renewable Energy Laboratory DO - 10.15121/1154908 KW - geothermal KW - EGS lab simulation KW - hydroshearing KW - granite KW - lab hydroshear KW - pressure KW - volume KW - load KW - pore pressure KW - temperature LA - English DA - 2014/07/29 PY - 2014 PB - Sandia National Laboratories T1 - Laboratory Evaluation of EGS Shear Stimulation-Test 001 UR - https://doi.org/10.15121/1154908 ER -
Export Citation to RIS
Bauer, Steve. Laboratory Evaluation of EGS Shear Stimulation-Test 001. Sandia National Laboratories, 29 July, 2014, Geothermal Data Repository. https://doi.org/10.15121/1154908.
Bauer, S. (2014). Laboratory Evaluation of EGS Shear Stimulation-Test 001. [Data set]. Geothermal Data Repository. Sandia National Laboratories. https://doi.org/10.15121/1154908
Bauer, Steve. Laboratory Evaluation of EGS Shear Stimulation-Test 001. Sandia National Laboratories, July, 29, 2014. Distributed by Geothermal Data Repository. https://doi.org/10.15121/1154908
@misc{GDR_Dataset_427, title = {Laboratory Evaluation of EGS Shear Stimulation-Test 001}, author = {Bauer, Steve}, abstractNote = {This is the results of an initial setup-shakedon test in order to develop the plumbing system for this test design. a cylinder of granite with offset holes was jacketed and subjected to confining pressure and low temperature (85C) and pore water pressure. Flow through the sample was developed at different test stages.}, url = {https://gdr.openei.org/submissions/427}, year = {2014}, howpublished = {Geothermal Data Repository, Sandia National Laboratories, https://doi.org/10.15121/1154908}, note = {Accessed: 2025-04-22}, doi = {10.15121/1154908} }
https://dx.doi.org/10.15121/1154908

Details

Data from Jul 29, 2014

Last updated Jun 27, 2017

Submitted Jul 30, 2014

Organization

Sandia National Laboratories

Contact

Steve Bauer

505.844.9116

Authors

Steve Bauer

Sandia National Laboratories

DOE Project Details

Project Lead Dan King

Project Number FY14 AOP 1.1.0.29

Share

Submission Downloads