Search GDR Data
Showing results 26 - 50 of 143.
Show
results per page.
Order by:
Available Now:
Topic
Technologies
Demonstration Sites
Data Type
Foam thermal stability was studies at Temple University in collaboration with Oak Ridge National Lab (ORNL). The goal of this project is to explore thermally stable foams as hydrofracking fluid media for potential applications in enhanced geothermal system (EGS). Data generated fr...
This data submission includes the raw time-lapse ERT (electrical resistivity tomography) monitoring data, flow system data, operator logs, E4D (https://e4d.pnnl.gov) inversion files, and metadata necessary to reproduce the 4D ERT inversion for the Oct. 24 through Nov. 7 2018 post-...
The Neal Hot Springs geothermal system lies in a left-step in a north-striking, west-dipping normal fault system, consisting of the Neal Fault to the south and the Sugarloaf Butte Fault to the north (Edwards, 2013). The Neal Hot Springs 3D geologic model consists of 104 faults and...
These data and test descriptions comprise a chilled circulation test conducted at the 164' fracture in the EGS Collab Experiment 1 testbed on the 4850 ft level of the Sanford Underground Research Facility. Descriptions of the meta data, design drawings for the flow testing system,...
This is a final technical report for the project: Foam Fracturing Study for Stimulation Development of Enhanced Geothermal Systems (EGS). The goal is to demonstrate the feasibility of foam fracturing in EGS applications. The project, led by Oak Ridge National Laboratory (ORNL), wa...
Mesh, properties, initial conditions, injection/withdrawal rates for modelling thermal, hydrological, and mechanical effects of fluid injection to and withdrawal from ground for Stockton University reservoir cooling system (aquifer storage cooling system), Galloway, New Jersey, fo...
This submission of Utilization Analysis data to the Geothermal Data Repository (GDR) node of the National Geothermal Data System (NGDS) is in support of Phase 1 Low Temperature Geothermal Play Fairway Analysis for the Appalachian Basin. The submission includes data pertinent to th...
Mesh, properties, initial conditions, injection/withdrawal rates for modeling thermal, hydrological, and mechanical effects of fluid injection to and withdrawal from ground for Stockton University reservoir cooling system (aquifer storage cooling system), Galloway, New Jersey, on ...
The San Emidio geothermal system is characterized by a left-step in a west-dipping normal fault system that bounds the western side of the Lake Range. The 3D geologic model consists of 5 geologic units and 55 faults. Overlying Jurrassic-Triassic metasedimentary basement is a ~500 ...
This dataset provides mass flux rates in kg/s from six (production and injection) wells at San Emidio at minute intervals from December 1, 2016 December 15, 2016. Files for injection wells are named with "IW", for instance "WellIW42-21SI.csv", and include negative flux rates. Fil...
This layer contains favorable geochemistry for high-temperature geothermal systems, as interpreted by Richard "Rick" Zehner. The data is compiled from the data obtained from the USGS. The original data set combines 15,622 samples collected in the State of Colorado from several sou...
Shapefiles and spreadsheets of structural data, including attitudes of faults and strata and slip orientations of faults.
Detailed geologic mapping of ~30 km2 was completed in the vicinity of the Columbus Marsh geothermal field to obtain critical structural data that would elucid...
The Tuscarora geothermal system sits within a ~15 km wide left-step in a major west-dipping range-bounding normal fault system. The step over is defined by the Independence Mountains fault zone and the Bull Runs Mountains fault zone which overlap along strike. Strain is transferre...
The submission includes FALCON input file and mesh for the an initial pressure-temperature simulation, and a second set for pressure-temperature-displacement simulation. All simulations are steady state. Data and input for the FORGE Phase 2 native state model were compiled from hi...
The FORGE team is making these fracture models available to researchers wanting a set of natural fractures in the FORGE reservoir for use in their own modeling work. They have been used to predict stimulation distances during hydraulic stimulation at the open toe section of well 1...
This data set includes the magnetotelluric (MT) data collected from October 21 to November 9, 2016 over the San Emidio geothermal field in Nevada by Quantec Geoscience USA Inc. on behalf of US Geothermal Inc. as part of a project entitled "A Novel Approach to Map Permeability Usi...
Raw magnetotelluric (MT) data covering the geothermal system at Raft River, Idaho. The data was acquired by Quantec Geoscience. This is a zipped file containing .edi raw MT data files.
Light Detection and Ranging (LiDAR) data for the Maui study area in South Maui, collected by Watershed Sciences, Inc. (WS) on October 29th, 2011 and from November 7th, 2011 to November 10th, 2011.
Accurate dynamic energy simulation is important for the design and sizing of district heating and cooling systems with geothermal heat exchange for seasonal energy storage. Current modeling approaches in building and district energy simulation tools typically consider heat conduct...
The Geothermal Exploration Artificial Intelligence looks to use machine learning to spot geothermal identifiers from land maps. This is done to remotely detect geothermal sites for the purpose of energy uses. Such uses include enhanced geothermal system (EGS) applications, especia...
Compilation of data (spreadsheet and shapefiles) for several low-temperature resource types, including isolated springs and wells, delineated area convection systems, sedimentary basins and coastal plains sedimentary systems. For each system, we include estimates of the accessible...
This layer traces apparent topographic and air-photo lineaments in the area around Pagosa springs in Archuleta County, Colorado. It was made in order to identify possible fault and fracture systems that might be conduits for geothermal fluids.
Geothermal fluids commonly utilize fa...
The McGinness Hills geothermal system lies in a ~8.5 km wide, north-northeast trending accommodation zone defined by east-dipping normal faults bounding the Toiyabe Range to the west and west-dipping normal faults bounding the Simpson Park Mountains to the east. Within this broad ...
This layer contains transmission network of Colorado as released by Xcel Energy.
Slip and Dilation Tendency in focus areas
Critically stressed fault segments have a relatively high likelihood of acting as fluid flow conduits (Sibson, 1994). As such, the tendency of a fault segment to slip (slip tendency; Ts; Morris et al., 1996) or to dilate (dilation tendency...
Google Map