Search GDR Data
Showing results 176 - 200 of 597.
Show
results per page.
Order by:
Available Now:
Topic
Technologies
Demonstration Sites
Data Type
This submission comprises two downloadable .zip archives. Each archive contains spreadsheets with 3-D data and a .txt document describing the data. The Mesh Files .zip download contains data regarding the lithologic contacts of the granitoid and overlying sedimentary basin fill. T...
Well data for the WO-2 well located in eastern Snake River Plain, Idaho. This data collection includes lithology reports, borehole logs, temperature at depth data, neutron density and gamma data, and rock strength parameters for the WO-2 well.
This collection of data has been ass...
This dataset is part of an effort to highlight the advantages of incorporating low-temperature (< 150 C) geothermal resource evaluation into the implementation of combined heat and power (CHP), and geothermal direct use (GDU) technologies (e.g., space heating and/or cooling). For...
Pressure, temperature, and flow data from open-hole, upper perforation, and lower perforation well stimulations gathered from various tools collected at well 58-32 during phase 2C.
Interpolated maps of heat flow, temperature gradient, and quartz geothermometers are included as TIF files. Zones of critical stress map is also included as a TIF file. The zones are given a 5km diameter buffer. The study area is only a part of the Basin and Range, but it does inc...
Directional Cooling-Induced Fracturing (DCIF) experiments were conducted on a short, cylindrical sample of Westerly granite (diameter = 4 inches, height ~ 2 inches). Liquid nitrogen was poured in a copper cup attached to the top of the sample, and the resulting acoustic emissions ...
This is a presentation on High-Temperature Testing of Proppants for EGS and Simulation of Electromagnetic Fracture Mapping Using Electrically-Conductive Proppants by Stevens Institute of Technology, presented by Dr. Cheng Chen. The project is evaluating the performance of electric...
Binary Costs and man-hour data supporting the technical and economic feasibility of utilizing the available unused heat to generate additional electric power from a binary power plant from the low-temperature brine at the Dixie Valley Geothermal Power Plant.
Binary costs and man-hour data supporting the technical and economic feasibility of utilizing the available unused heat to generate additional electric power from a binary power plant from the low-temperature brine at the Dixie Valley Geothermal Power Plant.
Shallow temperature surveys are useful in early-stage geothermal exploration to delineate surface outflow zones, with the intent to identify the source of upwelling, usually a fault. Detailed descriptions of the 2-meter survey method and equipment design can be found in Coolbaugh ...
High-pressure and high-temperature (HPHT) lost circulation material (LCM) rheology test results, LCM particle size distributions (PSD) analysis, and HPHT LCM fluid loss test results. Three academic papers / reports derived from this research are also presented.
This data submission includes several data components that were used to develop a conceptual model and power capacity-estimates of two low-temperature geothermal resources that define geothermal prospect A at Hawthorne, Nevada. Data are sourced from a combination of legacy publicl...
These data detail results from preliminary pH and reference electrode tests. The intention of this experiment is to test a novel High Temperature Chemical Sensing Tool for Distributed Mapping of Fracture Flow in EGS. 3 reference stability, a commercial reference, commercial stabil...
This dataset contains 1-second and hourly resolution water flow rate, pressure, temperature, and electrical conductivity data collected during Test 1 of the DEMO Fracture Thermal Energy Storage (FTES) project at the Sanford Underground Research Facility (SURF) between December 10,...
Dixie Valley Binary Costs reports. Includes cost and man-hour data supporting the technical and economic feasibility of utilizing the available unused heat to generate additional electric power from a binary power plant from the low-temperature brine at the Dixie Valley Geothermal...
This report presents thermal stability testing of fifteen Tracerco water tracers exposed to 250C for 48 hours. Tracer concentrations were compared using HPLC, with samples grouped based on retention time. Three tracers, HTP-001, HTP-002, and HTP-005, retained over 90% of their ori...
Cost and man-hour data supporting the technical and economic feasibility of utilizing the available unused heat to generate additional electric power from a binary power plant from the low-temperature brine at the Dixie Valley Geothermal Power Plant.
Data for December 2013
Dixie Valley Binary Plant Monthly Costs from February, 2014. Includes cost and man-hour data demonstrating the technical and economic feasibility of utilizing the available unused heat to generate additional electric power from a binary power plant from the low-temperature brine a...
Services associated with Binary Unit. Costs have been stripped. Demonstrates the technical and economic feasibility of utilizing the available unused heat to generate additional electric power from a binary power plant from the low-temperature brine at the Dixie Valley Geothermal ...
DOE Report Dixie Valley Binary project. Includes summary of data, operations, outages, and curtailments in order to support the techno-economic feasibility of utilizing the available unused heat to generate additional electric power from a binary power plant from the low-temperatu...
DOE summary report of data, operations, outages, and curtailments in order to support the techno-economic feasibility of utilizing the available unused heat to generate additional electric power from a binary power plant from the low-temperature brine at the Dixie Valley Geotherma...
Summary report of data, operations, outages, and curtailments in order to support the techno-economic feasibility of utilizing the available unused heat to generate additional electric power from a binary power plant from the low-temperature brine at the Dixie Valley Geothermal Po...
Orders associated with binary unit. Includes cost and man-hour data supporting the technical and economic feasibility of utilizing the available unused heat to generate additional electric power from a binary power plant from the low-temperature brine at the Dixie Valley Geotherma...
Files include Well Log information and raw data files for both GLADE East and GLADE West geothermal wells in the DJ Basin, Colorado. Data can be viewed with a PDF file viewer or log viewer capable of reading .LAS files. Log types included are Cement Bond Logs (CBL's), Mud Logs, a ...
Hourly steam use data for all significant buildings from the fiscal year (FY) 2017 (1 July 2016 30 June 2017) are provided. The total annual campus heating load in FY 2017 was about 0.81 trillion Btu (283,000 MWth-hrs).
The data are presented as a spreadsheet, detailing on an ho...
Google Map