Tracerco High Temperature Tracer Thermal Stability Testing - Report
This report presents thermal stability testing of fifteen Tracerco water tracers exposed to 250C for 48 hours. Tracer concentrations were compared using HPLC, with samples grouped based on retention time. Three tracers, HTP-001, HTP-002, and HTP-005, retained over 90% of their original concentration and passed the test. All other tracers showed significant degradation.
Citation Formats
TY - DATA
AB - This report presents thermal stability testing of fifteen Tracerco water tracers exposed to 250C for 48 hours. Tracer concentrations were compared using HPLC, with samples grouped based on retention time. Three tracers, HTP-001, HTP-002, and HTP-005, retained over 90% of their original concentration and passed the test. All other tracers showed significant degradation.
AU - Leggett, Smith
DB - Geothermal Data Repository
DP - Open EI | National Renewable Energy Laboratory
DO -
KW - geothermal
KW - energy
KW - water tracers
KW - thermal stability
KW - tracer test
KW - HPLC
KW - high-temperature testing
KW - retention time
KW - tracer degredation
KW - NaCl
KW - Parr reactor
KW - chemical tracer
KW - concentration retention
KW - high-temperature performance
KW - duplicate testing
KW - stability screening
KW - technical report
LA - English
DA - 2025/04/11
PY - 2025
PB - Texas Tech University
T1 - Tracerco High Temperature Tracer Thermal Stability Testing - Report
UR - https://gdr.openei.org/submissions/1729
ER -
Leggett, Smith. Tracerco High Temperature Tracer Thermal Stability Testing - Report. Texas Tech University, 11 April, 2025, Geothermal Data Repository. https://gdr.openei.org/submissions/1729.
Leggett, S. (2025). Tracerco High Temperature Tracer Thermal Stability Testing - Report. [Data set]. Geothermal Data Repository. Texas Tech University. https://gdr.openei.org/submissions/1729
Leggett, Smith. Tracerco High Temperature Tracer Thermal Stability Testing - Report. Texas Tech University, April, 11, 2025. Distributed by Geothermal Data Repository. https://gdr.openei.org/submissions/1729
@misc{GDR_Dataset_1729,
title = {Tracerco High Temperature Tracer Thermal Stability Testing - Report},
author = {Leggett, Smith},
abstractNote = {This report presents thermal stability testing of fifteen Tracerco water tracers exposed to 250C for 48 hours. Tracer concentrations were compared using HPLC, with samples grouped based on retention time. Three tracers, HTP-001, HTP-002, and HTP-005, retained over 90\% of their original concentration and passed the test. All other tracers showed significant degradation.},
url = {https://gdr.openei.org/submissions/1729},
year = {2025},
howpublished = {Geothermal Data Repository, Texas Tech University, https://gdr.openei.org/submissions/1729},
note = {Accessed: 2025-05-03}
}
Details
Data from Apr 11, 2025
Last updated Apr 17, 2025
Submitted Apr 11, 2025
Organization
Texas Tech University
Contact
Smith Leggett
Authors
Keywords
geothermal, energy, water tracers, thermal stability, tracer test, HPLC, high-temperature testing, retention time, tracer degredation, NaCl, Parr reactor, chemical tracer, concentration retention, high-temperature performance, duplicate testing, stability screening, technical reportDOE Project Details
Project Name Utah FORGE
Project Lead Lauren Boyd
Project Number EE0007080