Search GDR Data
Showing results 201 - 225 of 593.
Show
results per page.
Order by:
Available Now:
Topic
Technologies
Demonstration Sites
Data Type
The report details a thermal circulation test at Red Raider #2 at the Oil Field Technology Center (OTC) involving staged hot water injections and distributed temperature sensing (DTS) fiber optic measurements. It includes experimental setup, fluid flow and temperature data, therm...
Data from high temperature dynamic sealing tests for various fracture widths, at various temperatures (degrees F), with 5 wt.% bentonite-based mud containing various material fiber contents, at 100 to 400 psi differential pressure.
Data from pressure test and evaluation of the dy...
This dataset shows the capacity for Europium of media #1 and media #2 in a shakertable experiment. The experimental conditions were 150mL of 500ppm Eu solution, 2g of media, pH of 3.2, at ambient temperature.
This dataset includes temperature profiles from 30 boreholes throughout Maine that were selected for their depth, location, and lithologies encountered. Depths range from about 300 feet to 2,200 feet. Most of the boreholes selected for measurement were completed in granite becau...
Thermal profile data acquired using Silixa Ultima Distributed Temperature Sensor (DTS) at Cranfield, MS field test
Metadata for active distributed temperature survey (DTS) experiments at Guelph, Ontario Canada. This data that this metadata refers to was taken as part of the PoroTomo project. The metadata includes information about status, location, elevation, units, and other metadata.
The Snake River Plain (SRP), Idaho, hosts potential geothermal resources due to elevated groundwater temperatures associated with the thermal anomaly Yellowstone-Snake River hotspot. Project HOTSPOT has coordinated international institutions and organizations to understand subsurf...
This dataset provides an overview of the design, development, and technical specifications of for a community-scale geothermal heating and cooling system in Carbondale, Colorado. This thermal energy network (TEN) within the town's Three-Two Zero Energy District (32ZED) is part of ...
This dataset includes U.S. low-temperature heating and cooling demand at the county level in major end-use sectors: residential, commercial, manufacturing, agricultural, and data centers. Census division-level end-use energy consumption, expenditure, and commissioned power databas...
These reports contain information on the distributed temperature sensing (DTS), distributed strain sensing (DSS), and pressure monitoring during the stimulation of Well 16(B)78-32 at Utah FORGE, in April and May 2024. Reports include information on data collection and calibrations...
In order to gather data to assess sedimentary geothermal feasibility in Nevada and Utah, state oil and gas and geothermal databases were serached for well files and well logs. Well data from the Nevada Bureau of Mines and Geology oil and gas and geothermal databases was mined for ...
This submission comprises two downloadable .zip archives. Each archive contains spreadsheets with 3-D data and a .txt document describing the data. The Mesh Files .zip download contains data regarding the lithologic contacts of the granitoid and overlying sedimentary basin fill. T...
Well data for the WO-2 well located in eastern Snake River Plain, Idaho. This data collection includes lithology reports, borehole logs, temperature at depth data, neutron density and gamma data, and rock strength parameters for the WO-2 well.
This collection of data has been ass...
This dataset contains temperature, conductivity, and pressure data collected from a geothermal test well in Seward, Alaska, from October 31, 2023, through May 14, 2024. The data from the sensors are used to assess the potential for geothermal heat exchange along the shoreline of t...
Pressure, temperature, and flow data from open-hole, upper perforation, and lower perforation well stimulations gathered from various tools collected at well 58-32 during phase 2C.
Directional Cooling-Induced Fracturing (DCIF) experiments were conducted on a short, cylindrical sample of Westerly granite (diameter = 4 inches, height ~ 2 inches). Liquid nitrogen was poured in a copper cup attached to the top of the sample, and the resulting acoustic emissions ...
This collection includes datasets used for the analyses and modeling of low-temperature geothermal resources at the U.S. Army's Detroit Arsenal located in Warren, Michigan. This project file includes tabular and geospatial data accessed from publicly available repositories held by...
This is a presentation on High-Temperature Testing of Proppants for EGS and Simulation of Electromagnetic Fracture Mapping Using Electrically-Conductive Proppants by Stevens Institute of Technology, presented by Dr. Cheng Chen. The project is evaluating the performance of electric...
Binary Costs and man-hour data supporting the technical and economic feasibility of utilizing the available unused heat to generate additional electric power from a binary power plant from the low-temperature brine at the Dixie Valley Geothermal Power Plant.
Binary costs and man-hour data supporting the technical and economic feasibility of utilizing the available unused heat to generate additional electric power from a binary power plant from the low-temperature brine at the Dixie Valley Geothermal Power Plant.
High-pressure and high-temperature (HPHT) lost circulation material (LCM) rheology test results, LCM particle size distributions (PSD) analysis, and HPHT LCM fluid loss test results. Three academic papers / reports derived from this research are also presented.
These data detail results from preliminary pH and reference electrode tests. The intention of this experiment is to test a novel High Temperature Chemical Sensing Tool for Distributed Mapping of Fracture Flow in EGS. 3 reference stability, a commercial reference, commercial stabil...
This dataset contains 1-second and hourly resolution water flow rate, pressure, temperature, and electrical conductivity data collected during Test 1 of the DEMO Fracture Thermal Energy Storage (FTES) project at the Sanford Underground Research Facility (SURF) between December 10,...
Dixie Valley Binary Costs reports. Includes cost and man-hour data supporting the technical and economic feasibility of utilizing the available unused heat to generate additional electric power from a binary power plant from the low-temperature brine at the Dixie Valley Geothermal...
This report presents thermal stability testing of fifteen Tracerco water tracers exposed to 250C for 48 hours. Tracer concentrations were compared using HPLC, with samples grouped based on retention time. Three tracers, HTP-001, HTP-002, and HTP-005, retained over 90% of their ori...
Google Map