Search GDR Data
Showing results 51 - 75 of 150.
Show
results per page.
Order by:
Available Now:
Topic
Technologies
Demonstration Sites
Data Type
Geochemical data for cold groundwaters and produced geothermal fluids around the Utah FORGE site. The data is compiled into four tables in the attached Excel File. Table 1 is a compilation of compositions (anions, cations, weak acids, oxygen, hydrogen, and carbon isotopes) for c...
This dataset contains processed Neubrex Rayleigh Frequency Shift Distributed Strain Sensing data acquired in well 16B(78)-32 at the Utah FORGE site during August 2025 field operations. The data were collected during cross-well circulation testing from well 16A to well 16B and subs...
This dataset contains the known hydrocarbon reservoirs within the study area of the Geothermal Play Fairway Analysis for the Appalachian Basin (GPFA-AB) as part of Phase 1, Natural Reservoirs Quality Analysis. The final values for Reservoir Productivity Index (RPI) and uncertainty...
Shallow temperature surveys are useful in early-stage geothermal exploration to delineate surface outflow zones, with the intent to identify the source of upwelling, usually a fault. Detailed descriptions of the 2-meter survey method and equipment design can be found in Coolbaugh ...
This dataset comprises field logging data collected during chemical-based tool deployments at the Utah FORGE geothermal site, specifically at monitoring well 58-32 and production well 16B(78)-32. Data acquisition occurred during the Summer 2024 circulation testing campaign, with t...
The geocellular model of the St. Peter Sandstone was constructed for the University of Illinois at Urbana-Champaign DDU feasibility study. Starting with the initial area of review (18.0 km by 18.1 km [11.2 miles by 11.3 miles]) the boundaries of the model were trimmed down to 9.7 ...
The geocellular model of the Mt. Simon Sandstone was constructed for the University of Illinois at Urbana-Champaign DDU feasibility study. Starting with the initial area of review (18.0 km by 18.1 km [11.2 miles by 11.3 miles]) the boundaries of the model were trimmed down to 9.7 ...
The data includes the membrane properties and specifications used for multi-configuration membrane distillation desalination. In this study, membranes from CLARCOR, 3M, and Aquastill are tested in counter-current, co-current and air-gap configurations at Colorado School of Mines (...
Presented are trace element concentrations of minerals from the Salton Sea Geothermal Field (SSGF), located in the Imperial Valley, California. With a recent increase in demand for lithium, the area is actively being studied as a source of geothermal brine for lithium extraction. ...
Slip and dilation tendency on the Great Basin fault surfaces (from the USGS Quaternary Fault Database) were calculated using 3DStress (software produced by Southwest Research Institute).
Slip and dilation tendency are both unitless ratios of the resolved stresses applied to the f...
The purpose of this report is to investigate the effects of various parameters in a horizontal loop geothermal heat pump system. The obtained values include the temperature distribution over the entire system as well as the exiting temperature and bulk heat rate of the fluid. The ...
Numerical modeling on fused silica cylindrical materials for predicting overpressures required to fracture an homogeneous pure (surrogate) material with known mechanical properties similar to igneous rock materials and later compare these values to experimental overpressures obtai...
Lab-scale stimulation work on non-porous fused silica (similar mechanical properties to igneous rock) was performed using pure water, pure CO2 and water/CO2 mixtures to compare back to back fracturing performance of these fluids with PNNL's StimuFrac.
New high-quality tensor MT data at 122 sites, including the vertical magnetic field and utilizing ultra-remote referencing, have been acquired over the Utah FORGE project area. The results will be used to delineate the densities of faults and fractures in crystalline basement rock...
To prepare for its third phase, the Hawaii Play Fairway project conducted groundwater sampling and analyses in ten locations in the Hawaiian islands, magnetotelluric (MT) and gravity surveys, as well as calculations of 3D subsurface stress due to the weight of the rock underlying ...
A DEM of the Tularosa Basin was divided into twelve zones, each of which a ZR ratio was calculated for. This submission has a TIFF image of the zoning designations, along with a table with respective ZR ratio calculations in the metadata.
The primary results are in the table belo...
These files contain the output of a model calculation to simulate the pressure and temperature of fluid at Brady Hot Springs, Nevada, USA. The calculation couples the hydrologic flow (Darcy's Law) with simple thermodynamics. The epoch of validity is 24 March 2015. Coordinates are ...
This layer contains the weakened basement rocks. Isostatic gravity was utilized to identify structural basin areas, characterized by gravity low values reflecting weakened basement rocks. Together interpreted regional fault zones and basin outlines define geothermal "exploration f...
This submission contains raster files associated with several datasets that include earthquake density, Na/K geothermometers, fault density, heat flow, and gravity. Integrated together using spatial modeler tools in ArcGIS, these files can be used for play fairway analysis in rega...
The presented database includes water chemistry data and structural rating values for various geothermal features used for performing principal component (PC) and cluster analyses work to identify promising KGRAs and IHRAs in southern Idaho and southeastern Oregon. A brief note on...
We use ambient noise correlation (ANC) to create a detailed image of the subsurface seismic velocity at the Newberry EGS site down to 5 km. We collected continuous data for the 22 stations in the Newberry network, together with 12 additional stations from the nearby CC, UO and UW ...
Critically stressed fault segments have a relatively high likelihood of acting as fluid flow conduits (Sibson, 1994). As such, the tendency of a fault segment to slip or to dilate provides an indication of which faults or fault segments within a geothermal system are critically st...
Compressibility values were obtained in a range of pressures at 250degC by employing a fixed volume view cell completely filled with PAA aqueous solution and injecting CO2 at constant flow rate (0.3mL/min). Pressure increase as a function of supercritical CO2 (scCO2) mass fraction...
X-ray diffraction (XRD) results from cuttings samples collected during drilling of Utah FORGE well 16B(78)-32. The dataset includes XRD data for 77 samples taken between 3,120 and 10,977 feet measured depth (from the Kelly Bushing, 31 feet above ground level), with sampling interv...
This catalog contains microseismic event locations recorded during the April 2024 stimulation at the Utah FORGE site. Events were detected and located using a DAS-specific source imaging workflow that avoids conventional phase picking. Instead, STA/LTA-transformed DAS and downhole...
Google Map