The steel pipe experiment conducted in the lab was using 6 meter low-carbon steel pipe. We tested it with both dry and in-water condition. In the dry experimental setup, a coaxial cable acting as a return path in the air.
Rheology data obtained from flow loop tests, performed using different lost circulation materials (LCM) to study their effect on fluid rheology and wellbore hydraulics. The sealing performance of different LCM was tested using different fracture sizes. Five academic papers / repor...
This data file is for the hydroshear simulation lab test 3.2. The two previous hydroshear simulation lab tests are linked in the resources section as GDR submissions. In this test a sample of granite with a pre-cut (man made fracture) is confined, heated and differential stress is...
This is the results of an initial setup-shakedon test in order to develop the plumbing system for this test design. a cylinder of granite with offset holes was jacketed and subjected to confining pressure and low temperature (85C) and pore water pressure. Flow through the sample w...
Lab-scale stimulation was performed on Coso samples obtained from a single core (1623 feet TVD, reservoir Coso CGC 18-27) using StimuFrac and control fluid in the absence of stimuli-responsive polymer.
The coaxial-cable experiment conducted in the lab was with 80 m coaxial cable( RG-85). This experiment compares the TDR response between damaged and undamaged cable. For the damaged cable, the damaged section is in the middle (40 m). The amplitude of the data is mV with time (us).
Lab-scale stimulation work on non-porous fused silica (similar mechanical properties to igneous rock) was performed using pure water, pure CO2 and water/CO2 mixtures to compare back to back fracturing performance of these fluids with PNNL's StimuFrac.
This project focused on assessment and discovery of fluid-rock interaction in geothermal reservoirs. We accomplished work in four main areas: 1) fracture formation and the relationship between fluid flow and shear failure, 2) assessment of fracture geometry and fluid permeability ...
We synthesized PEGDA polymer hydrogel beads for cell embedding and compared REE biosorption with these beads via a gravity-driven flow through setup. One way to set up a flow through system is by cell encapsulation into polymer beads with a column setup similar to that used in th...
This file contains additional data for this test (hydroshear test 3.2). In this test a sample of granite with a pre-cut (man made fracture) is confined, heated and differential stress is applied. The max temperature in this this system development test is 95C. More test details ca...
Fabricated SiC diodes are tested in the temperature range of 300 degrees C to 600 degrees C.
Includes data for measured inert tracer breakthrough curves first reported in Hawkins (2020) (Water Resources Research). In addition, this submission includes the production well temperature measurements first reported in Hawkins et al. (2017a) (Water Resources Research, volume 53...
This submission contains DNA tracer data that supports the analysis and conclusions of the publication, "DNA tracer transport through porous media The effect of DNA length and adsorption." https://doi.org/10.1029/2020WR028382. This experiment used DNA as an artificial reservoir t...
Machine learning can be used to predict fault properties such as shear stress, friction, and time to failure using continuous records of fault zone acoustic emissions. The files are extracted features and labels from lab data (experiment p4679). The features are extracted with a n...
SMU Geothermal Lab developed a methodology to estimate shallow (1 km to 4 km) Enhanced Geothermal Systems (EGS) resource potential using an approach that utilizes recent geology and geophysical research along with new well data to improve the thermal conductivity model, mitigate i...
This data describes rare earth element adsorption onto E. coli cells engineered to express a lanthanide binding tag (LBT). We used a Great Salt Lake synthetic solution as the background matrix with Tb added to 1-10,000 ppb, concentrations much lower than the competing ions presen...
This dataset contains trace element concentrations from fluid samples collected during the August-September 2024 circulation test at Utah FORGE. Samples were taken from injection well 16A(78)-32, production well 16B(78)-32, and monitoring well 58-32 on four dates between August 16...
This dataset includes an Excel file with the results of direct shear tests to investigate the mechanical and geophysical response of saturated joints. Tests were conducted on induced tension-fractured Sierra White granite joints in a custom water pressurized chamber. The preparati...
The switchable polarity solvent forward osmosis (SPS FO) desalination process requires use of a polishing filtration step to remove trace quantities of draw solution from the product water stream. Selected nanofiltration (NF) and reverse osmosis (RO) membranes were tested for thei...
This dataset includes an Excel file with the results of B-value tests to determine the magnitude of the back pressure required for full saturation of Sierra White granite samples. Test were conducted on cylindrical rock specimens of Sierra White granite in a custom water pressuriz...
Submission includes data from laboratory slide-hold-slide tests, combined with flow through tests, conducted on Westerly granite with 30 degree sawcut. Tests were conducted with a constant confining pressure of 30 MPa with an average pore pressure of 10 MPa at temperatures of 23 a...
The utility of passive seismic emission tomography for mapping geothermal permeability has been tested at San Emidio in Nevada. The San Emidio study area overlaps a geothermal field in production since 1987 and another resource to the south of the production field. Passive seismic...
These data are Pacific Northwest National Lab inversions of an amalgamation of two surface gravity datasets: Davenport-Newberry gravity collected prior to 2012 stimulations and Zonge International gravity collected for the project "Novel use of 4D Monitoring Techniques to Improve...
This dataset contains raw experimental data from microfluidics-based injectivity and reversibility tests of ionic liquids (ILs) and alternative fluids (AFs). Fluids were injected through individual and combined microchannels at three temperatures (18 C, 50 C, and 80 C), and differ...
The data includes the membrane properties and specifications used for multi-configuration membrane distillation desalination. In this study, membranes from CLARCOR, 3M, and Aquastill are tested in counter-current, co-current and air-gap configurations at Colorado School of Mines (...