Included are datasets from wellbore breakout experiments conducted under triaxial conditions with varying fluid and temperature environments. This dataset serves as one of the experimental reports for the Role of Fluid and Temperature in Fracture Mechanics and Coupled Thermo-Hydro...
Submission includes data from laboratory slide-hold-slide tests, combined with flow through tests, conducted on Westerly granite with 30 degree sawcut. Tests were conducted with a constant confining pressure of 30 MPa with an average pore pressure of 10 MPa at temperatures of 23 a...
Laboratory experimental data on saw-cut interface of Westerly Granite and Utah Forge granitoid rocks. Experiments include velocity-stepping and fluid pressure stepping experiments. Mechanical data from 3 ISCO pumps connected to a Temco pressure vessel measure axial, confining and ...
High-pressure and high-temperature (HPHT) lost circulation material (LCM) rheology test results, LCM particle size distributions (PSD) analysis, and HPHT LCM fluid loss test results. Three academic papers / reports derived from this research are also presented.
Six samples were evaluated in unconfined and triaxial compression, their data are included in separate excel spreadsheets, and summarized in the word document. Three samples were plugged along the axis of the core (presumed to be nominally vertical) and three samples were plugged ...
Directional Cooling-Induced Fracturing (DCIF) experiments were conducted on three rectangular Westerly granite blocks (width=depth=4.0", height=2.0") which were preheated to 200, 400, and 600 degree C to induce damage (microcracks) with varying degrees. Liquid nitrogen was poured...
This project focused on assessment and discovery of fluid-rock interaction in geothermal reservoirs. We accomplished work in four main areas: 1) fracture formation and the relationship between fluid flow and shear failure, 2) assessment of fracture geometry and fluid permeability ...
Data includes Directional Cooling-Induced Fracturing (DCIF) testing data using westerly granite blocks. This submission includes data from two samples of westerly granite, lab sample 7 and 8. Files contain stress, temperature and acoustic emission data acquired during polyaxial, l...
Machine learning can be used to predict fault properties such as shear stress, friction, and time to failure using continuous records of fault zone acoustic emissions. The files are extracted features and labels from lab data (experiment p4679). The features are extracted with a n...
Included are results from shear reactivation experiments on laboratory faults pre-loaded close to failure and reactivated by the injection of fluid into the fault. The sample comprises a single-inclined-fracture (SIF) transecting a cylindrical sample of Westerly granite.
All expe...
This dataset contains results from controlled shear reactivation experiments performed on cylindrical Westerly and granitoid granite samples with a single inclined fracture. Laboratory faults were pre-loaded near failure and reactivated by fluid injection to examine relationships ...
Pressure data from a phreatic aquifer was collected in the summer of 2013 during Multi-frequency Oscillatory Hydraulic Tomography pumping tests. All tests were performed at the Boise Hydrogeophysical Research Site. The data will be inverted using a fast steady-periodic adjoint-bas...
This file contains additional data for this test (hydroshear test 3.2). In this test a sample of granite with a pre-cut (man made fracture) is confined, heated and differential stress is applied. The max temperature in this this system development test is 95C. More test details ca...
This data file is for the hydroshear simulation lab test 3.2. The two previous hydroshear simulation lab tests are linked in the resources section as GDR submissions. In this test a sample of granite with a pre-cut (man made fracture) is confined, heated and differential stress is...
Data here has been "pre-processed" and "analyzed" from the raw data submitted to the GDR previously (raw data files found at http://gdr.openei.org/submissions/479. doi:10.15121/1176944 after 30 September 2017). First, we submit .mat files which are the "pre-processed" data (must h...
These data detail results from preliminary pH and reference electrode tests. The intention of this experiment is to test a novel High Temperature Chemical Sensing Tool for Distributed Mapping of Fracture Flow in EGS. 3 reference stability, a commercial reference, commercial stabil...
California State University Long Beach evaluated hydraulic connectivity among geothermal wells using Periodic Hydraulic Testing (PHT) and Distributed Acoustic Sensing (DAS). The principal was to create a pressure signal in one well and observe the responding pressure signals in on...
Provided here are a final thermal conductivity test report, a drilling log, and a heat rejection log from Carbondale, CO. Also attached is a report made before drilling, which contains predictions on the hydrogeologic conditions of the drill site. The forty-eight (48.9) hour in-si...
This is the results of an initial setup-shakedon test in order to develop the plumbing system for this test design. a cylinder of granite with offset holes was jacketed and subjected to confining pressure and low temperature (85C) and pore water pressure. Flow through the sample w...
Fabricated SiC diodes are tested in the temperature range of 300 degrees C to 600 degrees C.
Drilling results from the microhole project at the Sandia High Operating Temperature test facility. The project is seeking to help reduce the cost of exploration and monitoring of geothermal wells and formations by drilling smaller holes. The tests were part of a control algorith...
Spreadsheet containing the raw measured data, calibrated data, and brief explanation of data for Test1 Stripa Granite Geomechanical/Geochemical Test. Stress on fracture ~20.7 MPa.
This archive contains data and a report from Pulse Interference Tests (PITs), which were conducted on September 4, 2024, immediately following a 30-day recirculation test at the Utah FORGE site. Injection and backflow were induced in well 16A(78)-32 while pressures were measured i...
Following the successful stimulation of Desert Peak target EGS well 27-15, a circulation test was initiated by injecting a conservative tracer (1,5-nds) in combination with a reactive tracer (7-amino-1,3-naphthalene disulfonate). The closest production well 74-21 was monitored ove...
This is a continuation of the rare earth element sorption study for shaker bath tests on 2g media #1 in 150mL brine #1 with different starting pH's at 70C. In a previous submission we reported data for shaker bath tests for brine #1 with starting pH's of 3.5, 4.5 and 5.5. In this ...