Search GDR Data
Showing results 151 - 168 of 168.
Show
results per page.
Order by:
Available Now:
Topic
Technologies
Demonstration Sites
Data Type
The steel pipe experiment conducted in the lab was using 6 meter low-carbon steel pipe. We tested it with both dry and in-water condition. In the dry experimental setup, a coaxial cable acting as a return path in the air.
The Snake River Plain (SRP), Idaho, hosts potential geothermal resources due to elevated groundwater temperatures associated with the thermal anomaly Yellowstone-Snake River hotspot. Project HOTSPOT has coordinated international institutions and organizations to understand subsurf...
This submission includes an input file, plot file, Fortran conversion file, and 3D data file from the simulation of the temperature profile within the Test Bed #1 of the EGS Collab project. The simulation was executed with PNNL's STOMP-GT simulator, which reads the input file, and...
The coaxial-cable experiment conducted in the lab was with 80 m coaxial cable( RG-85). This experiment compares the TDR response between damaged and undamaged cable. For the damaged cable, the damaged section is in the middle (40 m). The amplitude of the data is mV with time (us).
These data and test descriptions are from a set of primarily tensile hydraulic-fracture stimulations in wells E2-TC and E2-TU and a subsequent chilled water circulation test conducted by injecting in well E2-TU on the 4100 level of the Sandford Underground Research Facility (SURF)...
This submission is a follow-up to Distributed Temperature Sensing (DTS) measurements made in Brady observation well 56-1 during the PoroTomo field experiment conducted in March, 2016. The measurements in this data set were made on August 24, 2018 over an approximately 20 hour per...
The accompanying raw data is from tests of the TI SM28VLT32 flash memory module at temps of 200C, 225C, and 29C. Each data file is 3 columns and tab-delimited with the first column being the data address, the second column being the first byte of the data, and the third column bei...
NREL, as part of the Play Fairway Analysis (PFA) Retrospective and with assistance from PFA PIs, completed GeoRePORTs for the sites identified in Phases 1&2 of the DOE PFA projects.
The GeoRePORT (geothermal resource portfolio optimization and reporting technique) uses two factor...
In September 2013, an experiment using Distributed Acoustic Sensing (DAS) was conducted at Garner Valley, a test site of the University of California Santa Barbara (Lancelle et al., 2014). This submission includes one 45 kN shear shaker (called "large shaker" on the basemap) test ...
This test was conducted at the Chevron Cymric oilfield in the California central valley near Bakersfield. A reflected seismic signal was observed in all three components (x, y, z) of the 3-component Episensor geophone, as well as all phones on the single component array. The arriv...
DEEPEN stands for DE-risking Exploration of geothermal Plays in magmatic ENvironments.
Part of the DEEPEN project involved developing and testing a methodology for a 3D play fairway analysis (PFA) for multiple play types (conventional hydrothermal, superhot EGS, and supercritical...
Input and output files used for fault characterization through numerical simulation using iTOUGH2. The synthetic data for the push period are generated by running a forward simulation (input parameters are provided in iTOUGH2 Brady GF6 Input Parameters.txt [InvExt6i.txt]). In gene...
The EGS Collab Experiment took place at the Sanford Underground Research Facility at the Homestake gold mine in Lead, SD, USA. Distributed fiber optic sensing temperature data is included in this dataset for this experiment.
A single loop of custom fiber package was grouted into ...
The data is associated to the Fallon FORGE project and includes mudlogs for all wells used to characterize the subsurface, as wells as gravity, magnetotelluric, earthquake seismicity, and temperature data from the Navy GPO and Ormat. Also included are geologic maps from the USGS a...
Cymric oil field frequency domain electromagnetic (FEM) data with two parts of data labeled Part 1 and Part 2. Part 1 utilizes an electrical source line parallel to the receiver line, while Part 2 utilizes an electrical source line at a 75 deg angle to the receiver line. Data are ...
This experiment is testing the tube waves reflected from the bottom of the well. We put six single-channel geophones on the surface and a 24-channel downhole hydrophone into the well. The well is about 30 meters deep. Just a steel casing in the sand formation, no cement.
The FORGE team is making these fracture models available to researchers wanting a set of natural fractures in the FORGE reservoir for use in their own modeling work. They have been used to predict stimulation distances during hydraulic stimulation at the open toe section of well 1...
This dataset consists of drilling data (Pason data spreadsheets, daily reports, days v. depth, mud logs), Schlumberger logs (FMI, shear anisotropy analysis, memory, sonic, array induction/spectral density/dual spaced neutron/gamma ray/caliper, spectral GR/temperature, and Gardner ...