This dataset contains results from controlled shear reactivation experiments performed on cylindrical Westerly and granitoid granite samples with a single inclined fracture. Laboratory faults were pre-loaded near failure and reactivated by fluid injection to examine relationships ...
Included are experimental data recorded from shear experiments that specifically explore the link between fluid-injection rate and seismic moment resulting from shear reactivation of laboratory faults. Raw mechanical data from three experiments are included alongside corresponding...
The PoroTomo team has completed inverse modeling of the three data sets (seismology, geodesy, and hydrology) individually, as described previously. The estimated values of the material properties are registered on a three-dimensional grid with a spacing of 25 meters between nodes....
This dataset contains experimental and acoustic data from shear reactivation tests that investigate the relationship between fluid-injection rate, pore pressure distribution, and seismic moment during laboratory fault slip. It includes raw mechanical data and acoustic emission rec...
Slip and Dilation Tendency in focus areas
Critically stressed fault segments have a relatively high likelihood of acting as fluid flow conduits (Sibson, 1994). As such, the tendency of a fault segment to slip (slip tendency; Ts; Morris et al., 1996) or to dilate (dilation tendency...
Slip and dilation tendency on the Great Basin fault surfaces (from the USGS Quaternary Fault Database) were calculated using 3DStress (software produced by Southwest Research Institute).
Slip and dilation tendency are both unitless ratios of the resolved stresses applied to the f...
Input and output files used for fault characterization through numerical simulation using iTOUGH2. The synthetic data for the push period are generated by running a forward simulation (input parameters are provided in iTOUGH2 Brady GF6 Input Parameters.txt [InvExt6i.txt]). In gene...
ASCII text files containing grid-block name, X-Y-Z location, and multiple parameters from TOUGH2 simulation output of CO2 injection into an idealized single fault representing a dipping normal fault at the Desert Peak geothermal field (readable by GMS). The fault is composed of a ...
The dataset contains raw mechanical data from laboratory fault reactivation experiments on pre-stressed granite/granitoid samples, along with experimental parameters and MATLAB processing code for data deduction. The raw time-series data were recorded using a triaxial-shear appara...
Included are results from shear reactivation experiments on laboratory faults pre-loaded close to failure and reactivated by the injection of fluid into the fault. The sample comprises a single-inclined-fracture (SIF) transecting a cylindrical sample of Westerly granite.
All expe...
Included in this dataset is a spreadsheet with the primary fault information used in the basin model, a spreadsheet with earthquake magnitude estimates, and a figure showing location of faults and microseismicity in the Portland Basin
A recent study which adapts play fairway analysis (PFA) methodology to assess geothermal potential was conducted at three locations (Mount Baker, Mount St. Helens seismic zone, and Wind River valley) along the Washington Cascade Range (Forson et al. 2017). Potential field (gravity...
Detailed geologic mapping (1:24,000 scale), structural and geochemical analyses, and integration of available geophysical and well-field data were utilized to assess the structural controls of the Neal Hot Springs geothermal field in eastern Oregon. The geothermal field lies withi...
Included are experimental data recorded from shear experiments that explore the effects of pore pressure heterogeneity on microseismic character and fault slip timing resulting from shear reactivation of laboratory faults. Raw mechanical and acoustic data from 15 experiments are i...
Laboratory experimental data on saw-cut interface of Westerly Granite and Utah Forge granitoid rocks. Experiments include velocity-stepping and fluid pressure stepping experiments. Mechanical data from 3 ISCO pumps connected to a Temco pressure vessel measure axial, confining and ...
Critically stressed fault segments have a relatively high likelihood of acting as fluid flow conduits (Sibson, 1994). As such, the tendency of a fault segment to slip (slip tendency; Ts; Morris et al., 1996) or to dilate (dilation tendency; Td; Ferrill et al., 1999) provides an in...
Critically stressed fault segments have a relatively high likelihood of acting as fluid flow conduits (Sibson, 1994). As such, the tendency of a fault segment to slip (slip tendency; Ts; Morris et al., 1996) or to dilate (dilation tendency; Td; Ferrill et al., 1999) provides an in...
Laboratory slide-hold-slide tests were conducted in a conventional triaxial deformation configuration on 1-inch diameter cylindrical cores of Westerly granite bisected by a sawcut oriented at 30 degrees from vertical. Tests were conducted at a constant confining pressure of 30 MPa...
The 3D geologic model for the Fallon for site was constructed in EarthVision software using methods similar to (Moeck et al., 2009, 2010; Faulds et al., 2010b; Jolie et al., 2012, 2015; Hinz et al., 2013a; Siler and Faulds, 2013; Siler et al., 2016a, b) References are included in ...
Slip and Dilation Tendency in focus areas
Critically stressed fault segments have a relatively high likelihood of acting as fluid flow conduits (Sibson, 1994). As such, the tendency of a fault segment to slip (slip tendency; Ts; Morris et al., 1996) or to dilate (dilation tendency...
The EGS Collab experiment 2 was focused on testing shear stimulation techniques. Shear stimulation, in this case, means using hydraulic pressure to cause shear slip on preexisting fracture or fault planes such that the hydraulic conductivity of the fracture or fault increases. The...
Critically stressed fault segments have a relatively high likelihood of acting as fluid flow conduits (Sibson, 1994). As such, the tendency of a fault segment to slip (slip tendency; Ts; Morris et al., 1996) or to dilate (dilation tendency; Td; Ferrill et al., 1999) provides an in...
The Tuscarora geothermal system sits within a ~15 km wide left-step in a major west-dipping range-bounding normal fault system. The step over is defined by the Independence Mountains fault zone and the Bull Runs Mountains fault zone which overlap along strike. Strain is transferre...
This repository contains the electrical resistivity tomography (ERT) monitoring data that was collected before, during, and after shear stimulation attempts were conducted at EGS Collab. These tests were carried out on the SURF 4100 level during Experiment 2 in March, 2022. Flow a...
Structural controls of 426 geothermal systems in the Great Basin region including western Nevada, central Nevada, northwestern Nevada, northeastern Nevada, east-central Nevada, eastern California, southern Oregon, and western Utah were analyzed with literature research, air photos...
Google Map