The steel pipe experiment conducted in the lab was using 6 meter low-carbon steel pipe. We tested it with both dry and in-water condition. In the dry experimental setup, a coaxial cable acting as a return path in the air.
This report presents a preliminary assessment of the technical feasibility of utilizing underground thermal energy storage (UTES) and electric-driven heat pumps (EDHPs) to enable flexible behind-the-meter electric demand of buildings while meeting their thermal demands in an energ...
Rheology data obtained from flow loop tests, performed using different lost circulation materials (LCM) to study their effect on fluid rheology and wellbore hydraulics. The sealing performance of different LCM was tested using different fracture sizes. Five academic papers / repor...
This data file is for the hydroshear simulation lab test 3.2. The two previous hydroshear simulation lab tests are linked in the resources section as GDR submissions. In this test a sample of granite with a pre-cut (man made fracture) is confined, heated and differential stress is...
Active source ultrasonic data from lab experiments p5270 and p5271 including raw waveforms (WF) and mechanical data (mat). From the PSU team working on the "Machine Learning Approaches to Predicting Induced Seismicity and Imaging Geothermal Reservoir Properties" project. The fric...
This is the results of an initial setup-shakedon test in order to develop the plumbing system for this test design. a cylinder of granite with offset holes was jacketed and subjected to confining pressure and low temperature (85C) and pore water pressure. Flow through the sample w...
Lab-scale stimulation was performed on Coso samples obtained from a single core (1623 feet TVD, reservoir Coso CGC 18-27) using StimuFrac and control fluid in the absence of stimuli-responsive polymer.
The coaxial-cable experiment conducted in the lab was with 80 m coaxial cable( RG-85). This experiment compares the TDR response between damaged and undamaged cable. For the damaged cable, the damaged section is in the middle (40 m). The amplitude of the data is mV with time (us).
A table of cement formulations tested by Brookhaven National Laboratory in 2016-2017 in the frame of the "Self-healing and Re-Adhering Cements with Improved Toughness at Casing and Formation Interfaces for Geothermal Wells" project.
Lab-scale stimulation work on non-porous fused silica (similar mechanical properties to igneous rock) was performed using pure water, pure CO2 and water/CO2 mixtures to compare back to back fracturing performance of these fluids with PNNL's StimuFrac.
This project focused on assessment and discovery of fluid-rock interaction in geothermal reservoirs. We accomplished work in four main areas: 1) fracture formation and the relationship between fluid flow and shear failure, 2) assessment of fracture geometry and fluid permeability ...
We synthesized PEGDA polymer hydrogel beads for cell embedding and compared REE biosorption with these beads via a gravity-driven flow through setup. One way to set up a flow through system is by cell encapsulation into polymer beads with a column setup similar to that used in th...
This file contains additional data for this test (hydroshear test 3.2). In this test a sample of granite with a pre-cut (man made fracture) is confined, heated and differential stress is applied. The max temperature in this this system development test is 95C. More test details ca...
The Geothermal Limitless Approach to Drilling Efficiencies (GLADE) project was undertaken in Denver-Julesburg (DJ) Basin Colorado to evaluate whether advanced oil and gas drilling practices could be adapted to improve geothermal well construction in deep, hot, hard-rock environmen...
We developed a model for fracture production produced during detonation of an explosive mixture in a 10m packed off section of a shallow borehole. The model is based upon an actual field and lab experiments on low-damage borehole fracturing performed at Sandia National Labs by Mar...
Fabricated SiC diodes are tested in the temperature range of 300 degrees C to 600 degrees C.
This dataset contains final reports regarding stress measurements, permeability measurements, and mechanical properties from the core testing of well 58-32, in PDF format, and spreadsheets containing tables from the reports as part of Utah FORGE Phase 2B. Please refer to the repor...
Includes data for measured inert tracer breakthrough curves first reported in Hawkins (2020) (Water Resources Research). In addition, this submission includes the production well temperature measurements first reported in Hawkins et al. (2017a) (Water Resources Research, volume 53...
A fundamental issue in microhole drilling is that delivering high weight-on-bit (WOB), high torque rotational horsepower to a conventional drill bit does not scale down to the hole sizes necessary to realize the envisioned cost savings An optimization algorithm called a golden sec...
This submission contains DNA tracer data that supports the analysis and conclusions of the publication, "DNA tracer transport through porous media The effect of DNA length and adsorption." https://doi.org/10.1029/2020WR028382. This experiment used DNA as an artificial reservoir t...
Machine learning can be used to predict fault properties such as shear stress, friction, and time to failure using continuous records of fault zone acoustic emissions. The files are extracted features and labels from lab data (experiment p4679). The features are extracted with a n...
Map of the PoroTomo Laboratory at Brady Field, Nevada. Map includes locations of GPS Stations, Shaker Stations, Vibroseis Sites, Seismometers, Fiber-Optic Cables, and wells
SMU Geothermal Lab developed a methodology to estimate shallow (1 km to 4 km) Enhanced Geothermal Systems (EGS) resource potential using an approach that utilizes recent geology and geophysical research along with new well data to improve the thermal conductivity model, mitigate i...
A study comparing the REE sorption characteristics of fresh ligand-based sorption media and media partially loaded with REEs when exposed to a simulated geothermal brine with known mineral concentrations, REE7. Sorption rates were tested using microcosm shaker tests. Results sugg...