Description of a conceptual commercial process to remove rare earth elements (REEs) from geothermal brine, based on a small-scale laboratory experiment to load, strip, and regenerate a ligand-based media used to adsorb REEs from a simulated brine doped with known mineral concentra...
This document describes the method and results of an in-situ experiment used to confirm that ligand bleed from a sorptive media can be contained. The experiment focused on maintaining the media's sorption of rare earth elements (REE) obtained from a simulated geothermal brine dop...
This is a dataset for a 200ppm europium solution sent through a column with 12g of media #1 at pH of 3.2. This column experiment was run at ambient temperature at a flow rate of 2mL/min.
Experimental results from several studies exploring the impact of pH and acid volume on the stripping of rare earth elements (REEs) loaded onto ligand-based media via an active column. The REEs in this experiment were loaded onto the media through exposure to a simulated geother...
This data set shows the different loading capacities of Media #1 and Media #2 in a high and low salt content brine matrix at different liquid to solid ratio's. These data sets are shaker bath tests on media #1 and media #2 in brine's #1 and #2 at 500mL-.5g(1000-1 ratio), 150mL-.75...
Study of rare earth element (REE) uptake from geothermal brine simulant by column loading, metal recovery through stripping, and regeneration of column for re-loading. Simulated brine testing.
This dataset shows the capacity for Europium of media #1 and media #2 in a shakertable experiment. The experimental conditions were 150mL of 500ppm Eu solution, 2g of media, pH of 3.2, at ambient temperature.
This data is from a regeneration study from a dynamic column extraction experiment where we ran a solution of REE's through a column of media #1 then stripped the REE's off the media using 2M HNO3 solution. We then re-equilibrated the media and repeated the process of running a RE...
A study comparing the REE sorption characteristics of fresh ligand-based sorption media and media partially loaded with REEs when exposed to a simulated geothermal brine with known mineral concentrations, REE7. Sorption rates were tested using microcosm shaker tests. Results sugg...
A study exploring sorption and stripping characteristics of sorption media when simulated geothermal brines are degassed or not degassed. Experiments were done at 70degC. The brines used in this study were formulated by Tusaar. The two brines used/simulated are labeled 1M and 1C...
This dataset shows the ability of media #1 to be loaded with REE's, stripped of the REE's sequestered, regenerated, and reused over many cycles.
This dataset described shaker table experiments ran with sieved 50 +100 mesh media #1 in brine #1 that have 2ppm each of the 7 REE metals at different starting pH's of 3.5, 4.5, and 5.5. The experimental conditions are 2g media to 150mL of REE solution, at 70C.
This dataset includes chemistry of geothermal water samples of the Camas Prairie area in Idaho. The samples included in this dataset were collected over the period of 2016-2019. Collection/analysis of new water samples and compilation of existing water chemistry database were cond...
Solution chemical analysis data for magnetic core shell sorbent materials. Deionized water and brine solutions were spiked with five rare earth elements and the solutions analyzed after approximately 5 minutes exposure to the sorbent particles.
Measurements of particle extraction efficiency under various flow rate and magnetic power conditions
An important consideration for the process design is cell immobilization-enabled flow-through operation. Large-scale biosorption relies on cells that are immobilized on a supporting substrate and used to 'attract' metal ions. Cell immobilization allows easy separation of the feed...
This data describes rare earth element adsorption onto E. coli cells engineered to express a lanthanide binding tag (LBT). We used a Great Salt Lake synthetic solution as the background matrix with Tb added to 1-10,000 ppb, concentrations much lower than the competing ions presen...
This submission includes data collected from experiments on the performance of rare earth adsorption by immobilized bacteria that accompany the FY18 Q2 and Q3 quarter reports. Relevant information from these reports is included in a resource below. The spreadsheet below includes d...
We have conducted aqueous speciation analyses of the Great Salt Lake (GSL) brine sample (Table 1) and a mock geo sample (Table 2) spiked with 1 ppb Tb and 100 ppb Tb. The GSL speciation (Figure 1) aligns with our basic speciation expectations that strong carbonate complexes would ...
LBT (lanthanide binding tag) cells were grown overnight in LB media with 0.05% Amp. 1:100 subculture taken from overnights, grown for 2 hours. LBT was induced with 0.002% arabinose added for 3 hours. REE adsorption was done by combining 350 ul (0.25% 1M MES, 12.5 uM Tb, and 12.5 u...
We summarized the FY17 and part of FY18 results of the analysis of the effect of several parameters (e.g., total dissolved solids, specific competing metals, pH, and temperature) on REE recovery from geothermal brine in a manuscript that was submitted to Environmental Science & Te...
The work evaluates, develops and demonstrates flexible, scalable mineral extraction technology for geothermal brines based upon solid phase sorbent materials with a specific focus upon rare earth elements (REEs). The selected organic and inorganic sorbent materials demonstrated h...
This GDR submission is an interim technical report and raw data files from the first year of testing on functionalized nanoparticles for rare earth element extraction from geothermal fluids. The report contains Rare Earth Element uptake results (percent removal, mg Rare Earth Ele...
The work evaluates, develops and demonstrates flexible, scalable mineral extraction technology for geothermal brines based upon solid phase sorbent materials with a specific focus upon rare earth elements (REEs). The selected organic and inorganic sorbent materials (silica and MOF...
The current uncertainty in the global supply of rare earth elements (REEs) necessitates the development of novel extraction technologies that utilize a variety of REE source materials. Herein, we examined the techno-economic performance of integrating a biosorption approach into a...