Utah FORGE: 58-32 Injection and Packer Performance, April and May 2019

This is a PDF format summary report regarding the performance of a packer, which failed, and bridge plug used during the injection program in Utah FORGE deep Well 58-32, April and May, 2019.
McLennan, J. and Podgorney, R. Energy and Geoscience Institute at the University of Utah
Mar 22, 2020
1 Resources
0 Stars
Publicly accessible

Foam Fracturing Study for Stimulation Development of Enhanced Geothermal Systems

This is a final technical report for the project: Foam Fracturing Study for Stimulation Development of Enhanced Geothermal Systems (EGS). The goal is to demonstrate the feasibility of foam fracturing in EGS applications. The project, led by Oak Ridge National Laboratory (ORNL), wa...
Wang, H. et al Oak Ridge National Laboratory
May 17, 2022
3 Resources
0 Stars
Publicly accessible

Utah FORGE: Well 16B(78)-32 Distributed Temperature Sensing Data from April and May 2024

This dataset includes Neubrex Energy Services fiber optic distributed temperature sensing (DTS) data from well 16B(78)-32 during stimulation and circulation, including interaction with well 16A(78)-32, during April and May 2024. The DTS data are stored in HDF5 file format and are ...
Jurick, D. and Guzik, A. Energy and Geoscience Institute at the University of Utah
Jul 08, 2024
1 Resources
0 Stars
Publicly accessible

Performance, Cost, and Financial Parameters of Geothermal District Heating Systems for Market Penetration Modeling under Various Scenarios

The U.S. Department of Energy Geothermal Vision (GeoVision) Study is currently looking at the potential to increase geothermal deployment in the U.S. and to understand the impact of this increased deployment. This paper reviews 31 performance, cost, and financial parameters as inp...
Beckers, K. and Young, K. National Renewable Energy Laboratory
Mar 23, 2017
1 Resources
1 Stars
Publicly accessible

Full Moment Tensor Inversion Software

The link points to a website at NCEDC to download the full moment tensors inversion software The moment tensor analysis conducted in the current project is based on the full moment tensor model described in Minson and Dreger (2008). The software including source, examples and tut...
Gritto, R. and Dreger, D. Array Information Technology
Oct 31, 2018
1 Resources
0 Stars
Publicly accessible

Utah FORGE: Optimization of a Plug-and-Perf Stimulation (Fervo Energy)

Information around the plug-and-perf treatment design at Utah FORGE by Fervo Energy. Objective and Purpose: Develop a multistage hydraulic stimulation approach designed specifically to target the top three factors that control the technical and commercial viability of an EGS sys...
Norbeck, J. et al Fervo Energy
Feb 08, 2023
3 Resources
1 Stars
Publicly accessible

Utah FORGE: Drilling Data for Student Competition

Diagnostic drilling data (Pason log files) from Well 58-32 (previously labeled MU-ESW1), which was drilled near Milford Utah during Phase 2B of the FORGE Project to confirm geothermal reservoir characteristics met requirements for the final FORGE site. This dataset includes both ...
Podgorney, R. et al Idaho National Laboratory
Dec 07, 2018
2 Resources
0 Stars
Publicly accessible

Electronics Platform and Temperature Sensor System For Enhanced Geothermal Systems Capable of 300C

Final research performance report for an electronics platform and temperature sensor system for enhanced geothermal systems (EGS) capable of 300 degrees Celcius.
Vert, A. GE Global Research
Jan 01, 2012
1 Resources
0 Stars
Publicly accessible

Technology Development and Field Trials of EGS Drilling Systems at Chocolate Mountain

Polycrystalline diamond compact (PDC) bits are routinely used in the oil and gas industry for drilling medium to hard rock but have not been adopted for geothermal drilling, largely due to past reliability issues and higher purchase costs. The Sandia Geothermal Research Departmen...
Knudsen, S. et al Sandia National Laboratories
Jan 01, 2012
3 Resources
0 Stars
Publicly accessible

Lab-Scale Stimulation Results on Surrogate Fused Silica Samples

Lab-scale stimulation work on non-porous fused silica (similar mechanical properties to igneous rock) was performed using pure water, pure CO2 and water/CO2 mixtures to compare back to back fracturing performance of these fluids with PNNL's StimuFrac.
Fernandez, C. Pacific Northwest National Laboratory
Jul 06, 2016
1 Resources
0 Stars
Publicly accessible

Fracture Sustainability Test, Pre and Post-Test Photomicrographs

The primary objective of this research is to understand how different rock types, mineral and fluid compositions, and fracture surface textures determine the longevity of fracture apertures, so that selection of reservoir rock can be economically optimized to reduce future refract...
Dobson, P. et al Lawrence Berkeley National Laboratory
Sep 26, 2016
9 Resources
0 Stars
Publicly accessible

Utah FORGE 2439: Well 16B(78)-32 Field-Test Data from Mini-Frac Tests

This submittal includes the field-test data collected during stress tests conducted in the Utah FORGE 16B(78)-32 wellbore to measure/characterize the stresses in the geothermal reservoir. The type of stress test performed is referred to as a mini-frac test or a micro-frac test. Th...
Kelley, M. et al Battelle Memorial Institute
Jul 02, 2023
4 Resources
0 Stars
Publicly accessible

Utah FORGE: Wells 16A(78)-32 and 16B(78)-32 Extended Circulation Test Data August and September 2024

The dataset includes data collected during an extended circulation test conducted at the Utah FORGE site between August 8 and September 5, 2024. It provides uncorrected, raw digital data from the test, along with calibration information and a final report detailing the test proced...
McLennan, J. et al Energy and Geoscience Institute at the University of Utah
Oct 11, 2024
1 Resources
0 Stars
Publicly accessible

Post-Test SEM Examination of Brady Core, Desert Peak Core, and Stripa Granite Samples

As part of the shear-induced permeability test of Brady well BCH-03, Desert Peak well DP 35-13, and Stripa granite samples, the three post-test (reacted) rock samples were examined using a Scanning Electron Microscope (SEM). The SEM images of the core and elemental analysis are in...
Kneafsey, T. et al Lawrence Berkeley National Laboratory
Dec 23, 2015
4 Resources
0 Stars
Publicly accessible

High Temperature Chemical Sensing Tool: Preliminary pH and reference electrode test results

Project: High Temperature Chemical Sensing Tool for Distributed Mapping of Fracture Flow in EGS. Preliminary pH and reference electrode test results.
Cieslewski, G. Sandia National Laboratories
Sep 30, 2014
6 Resources
0 Stars
Publicly accessible

SiC Diode Test Data

Fabricated SiC diodes are tested in the temperature range of 300 degrees C to 600 degrees C.
Gilbert, G. Sandia National Laboratories
Aug 01, 2014
1 Resources
0 Stars
Publicly accessible

Utah FORGE 3-2514: Strain Sensing Array for Deformation Characterization 2024 Annual Workshop Presentation

This is a presentation on the Strain Sensing Array to characterize deformation at the FORGE site project by Clemson University, presented by Lawrence Murdoch. The project's objective was to evaluate the feasibility of measuring and interpreting tensor strain data to improve the pe...
Murdoch, L. et al Energy and Geoscience Institute at the University of Utah
Aug 13, 2024
1 Resources
0 Stars
Publicly accessible

Utah FORGE: RESMAN Well 16A(78)-32 and 16B(78)-32 Stimulation and Circulation Tracer Test Results 2024

This dataset contains tracer test results from stimulation and circulation experiments conducted on the Utah FORGE wells 16A(78)-32 and 16B(78)-32 during 2024. The data was collected by RESMAN Energy Technology and includes detailed tracer analysis from flowback, short and extende...
Hartvig, S. et al RESMAN Energy Technology
Jan 14, 2025
2 Resources
0 Stars
Curated

Shear Induced Permeability Test: Stripa Granite Temperature Pressure and Displacement Data

Spreadsheet containing the raw measured data, calibrated data, and brief explanation of data for Test1 Stripa Granite Geomechanical/Geochemical Test. Stress on fracture ~20.7 MPa.
Kneafsey, T. Lawrence Berkeley National Laboratory
Jun 21, 2014
1 Resources
0 Stars
Publicly accessible

Utah FORGE: Wells 16A(78)-32 and 16B(78)-32 Stimulation Pressure and Circulation Data April, 2024

This dataset consists of all of the pressure pumping data for Utah FORGE Well16A78-32 fracturing stages, Well 16B78-32 fracturing stages, and a 9-hour circulation test which took place after all of the frac plugs were drilled out. Fracturing in the wells took place in stages from ...
England, K. Energy and Geoscience Institute at the University of Utah
Jun 03, 2024
4 Resources
0 Stars
Publicly accessible

EGS-Collab Experiment 1: Time-lapse ERT Data and E4D Inversion Files for 10-24-2018 through 11-07-2018 Flow Test

This data submission includes the raw time-lapse ERT (electrical resistivity tomography) monitoring data, flow system data, operator logs, E4D (https://e4d.pnnl.gov) inversion files, and metadata necessary to reproduce the 4D ERT inversion for the Oct. 24 through Nov. 7 2018 post-...
Johnson, T. Pacific Northwest National Laboratory
Jul 30, 2021
5 Resources
0 Stars
Publicly accessible

Utah FORGE: Well 16A(78)-32 Stimulation Tracer Test Results

This archive contains data from the tracer test performed during the Utah FORGE well 16A(78)-32 stimulation. This includes: 1. the raw data file from Pason in the csv format; 2. a one-page Word document from Pason that explains the headers and units used in their data file; 3. an...
Rose, P. and Barker, B. Energy and Geoscience Institute at the University of Utah
Sep 16, 2022
1 Resources
0 Stars
Publicly accessible

Utah FORGE 3-2417: Pulsed Interference Tests at Wells 16A(78)-32 and 16B(78)-32 September 2024

This archive contains data and a report from Pulse Interference Tests (PITs), which were conducted on September 4, 2024, immediately following a 30-day recirculation test at the Utah FORGE site. Injection and backflow were induced in well 16A(78)-32 while pressures were measured i...
W Becker, M. et al Rice University
Mar 18, 2025
3 Resources
0 Stars
Publicly accessible

Test Report for Detonation Velocity Measurements

Test report for detonation velocity measurements. A series of tests were conducted to determine reaction rate and general behavior of aluminum (AL) and magnesium (MG) powder mixtures (metalized explosives) with Bullseye double-base smokeless propellant. Given the indeterminate sen...
Grubelich, M. Sandia National Laboratories
Jan 13, 2014
1 Resources
0 Stars
Publicly accessible

First Tracer Test After Circulation in Desert Peak 27-15

Following the successful stimulation of Desert Peak target EGS well 27-15, a circulation test was initiated by injecting a conservative tracer (1,5-nds) in combination with a reactive tracer (7-amino-1,3-naphthalene disulfonate). The closest production well 74-21 was monitored ove...
Rose, P. University of Utah
Nov 16, 2013
1 Resources
0 Stars
Publicly accessible
12345Next >>
  • About the GDR
  • Partners & Sponsors
  • Disclaimers
  • Developer Services
  • The GDR is the submission point for all data collected from research funded by the U.S. Department of Energy's Geothermal Technologies Office.
  • Content is available under Creative Commons Attribution 4.0 unless otherwise noted.

Privacy Policy Notification

This site uses cookies to store and share user preferences with other OpenEI sites, and uses Google Analytics to collect anonymous user information such as which pages are visited, for how often, and what searches or other webpages may have led users here. You can prevent Google Analytics from recognizing you on return visits to this site by disabling cookies on your browser or by installing a Google Analytics Opt-out Browser Add-on. By clicking "Accept" you agree this site can store cookies on your device and disclose information to OpenEI and Google Analytics in accordance with our privacy policy.

OpenEI Privacy Policy Google Analytics Terms of Service