Search GDR Data
Showing results 1 - 25 of 30.
Show
results per page.
Order by:
Available Now:
Topic
Technologies
Demonstration Sites
Data Type
This folder contains the GEOPHIRES codes and input files for running the base case scenarios for the six deep direct-use (DDU) projects. The six DDU projects took place during 2017-2020 and were funded by the U.S. Department of Energy Geothermal Technologies Office. They investiga...
The objectives of this project were to (1) perform a literature review of sedimentary geothermal resources, (2) identify data sources and develop data-collection methodologies that characterize selected resources, (3) screen sedimentary basins and formations for sedimentary geothe...
This data set includes sidewall core data from well Cornell ESH #1 (API 31109300030000), known as the Cornell University Borehole Observatory, or CUBO. It is a stratigraphic well drilled to characterize potential EGS resources. The Drilling commenced on June 21, 2022 and total dep...
This data set includes drill rig drilling parameters from well Cornell ESH #1 (API 31109300030000), known as the Cornell University Borehole Observatory, or CUBO. It is a stratigraphic well drilled to characterize potential EGS resources. The Drilling commenced on June 21, 2022 an...
The project provides an updated Energy Return on Investment (EROI) for Enhanced Geothermal Systems (EGS). Results incorporate Argonne National Laboratory's Life Cycle Assessment and base case assumptions consistent with other projects in the Analysis subprogram.
EROI is a ratio o...
This data set includes wireline geophysical data from well Cornell ESH #1 (API 31109300030000), known as the Cornell University Borehole Observatory, or CUBO. It is a stratigraphic well drilled to characterize potential EGS resources. The Drilling commenced on June 21, 2022 and to...
This data set includes wireline geophysical data from well Cornell ESH #1 (API 31109300030000), known as the Cornell University Borehole Observatory, or CUBO. It is a stratigraphic well drilled to characterize potential EGS resources. The Drilling commenced on June 21, 2022 and to...
This report is the third in a series of reports sponsored by the U.S. Department of Energy Geothermal Technologies Program in which a range of water-related issues surrounding geothermal power production are evaluated. The first report made an initial attempt at quantifying the li...
This report documents the results of investigations dealing with the concentrations and availabilities of strategic, critical and valuable materials (SCVM) in produced waters from geothermal and hydrocarbon reservoirs (50-250 degrees C) in Idaho, Nevada, New Mexico, Oregon, and Ut...
The objective of this field test is to validate several technologies for non-invasive well integrity assessment using existing wells with a known completion. The tests were made at the Cymric oil field, which is a steam flood operation. The wells therefore undergo similar downhole...
The steel pipe experiment conducted in the lab was using 6 meter low-carbon steel pipe. We tested it with both dry and in-water condition. In the dry experimental setup, a coaxial cable acting as a return path in the air.
A fundamental issue in microhole drilling is that delivering high weight-on-bit (WOB), high torque rotational horsepower to a conventional drill bit does not scale down to the hole sizes necessary to realize the envisioned cost savings An optimization algorithm called a golden sec...
The coaxial-cable experiment conducted in the lab was with 80 m coaxial cable( RG-85). This experiment compares the TDR response between damaged and undamaged cable. For the damaged cable, the damaged section is in the middle (40 m). The amplitude of the data is mV with time (us).
This paper describes the methodology used to define the baseline exploration suite of techniques (baseline), as well as the approach that was used to create the cost and time data set that populates the baseline. The resulting product, an online tool for measuring impact, and the ...
The large scale Deep Direct Use (DDU) geothermal project in the low temperature environment of the Illinois Basin requires drilling and completing two wells. One well would be the extraction (producing) well and would be built to deliver a flow rate of approximately 6000 barrels ...
This test was conducted at the Chevron Cymric oilfield in the California central valley near Bakersfield. A reflected seismic signal was observed in all three components (x, y, z) of the 3-component Episensor geophone, as well as all phones on the single component array. The arriv...
The main goal of this project is to develop an annular isolation system capable to withstand geothermal downhole conditions and mitigate the problems experienced by conventional packers in FORGE wells. This large-scale set-up report is about the system that has been constructed to...
The main goal of this project is to develop an annular isolation system capable to withstand geothermal downhole conditions and mitigate the problems experienced by conventional packers in FORGE wells. This pipe preparation report is based on the test pipe that was procured and pr...
The main goal of this project is to develop an annular isolation system capable to withstand geothermal downhole conditions and mitigate the problems experienced by conventional packers in FORGE wells. This materials testing report is based on thermoplastic and elastomeric materia...
Cymric oil field frequency domain electromagnetic (FEM) data with two parts of data labeled Part 1 and Part 2. Part 1 utilizes an electrical source line parallel to the receiver line, while Part 2 utilizes an electrical source line at a 75 deg angle to the receiver line. Data are ...
The main goal of this project is to develop an annular isolation system capable to withstand geothermal downhole conditions and mitigate the problems experienced by conventional packers in FORGE wells. This presentation outlines the work in rock modelling and interaction with the ...
The objective of this project is to use a multi-disciplinary, three-tiered approach to assess the geothermal resource and determine the feasibility of implementing a large-scale, direct-use facility for the Hawthorne Army Depot (HAD) and the various town and county facilities in H...
This experiment is testing the tube waves reflected from the bottom of the well. We put six single-channel geophones on the surface and a 24-channel downhole hydrophone into the well. The well is about 30 meters deep. Just a steel casing in the sand formation, no cement.
The following information is provided about the design of deeps wells constructed in the Illinois Basin to store, sequester, or dispose of CO2, natural gas, and industrial wastes.
The problem of loss circulation in geothermal wells is inherently challenging due to high temperatures, brittle rocks, and presence of abundant fractures. Because of the inherent challenges in geothermal environments, there are limitations in selecting proper lost circulation mate...
Google Map